General description 

 

The  transmitters  T3110  are  designed  for  measurement  of  ambient 
temperature  and  relative  humidity  of  air  without  aggressive  substances. 
Measured  values  are  converted  to  other  humidity  interpretation:  dew  point 
temperature,  absolute  humidity,  specific  humidity,  mixing  ratio,  specific 
enthalpy. 

Measured  and  computed  values  are  displayed  on  a  two-line  LCD  display. 
The first line displays temperature 

(ºC / ºF). Value displayed on the second 

line  is  selectable  among  relative  humidity  and  computed  value.  It  is  also 
possible to display both readings with cyclic overwriting (4 seconds interval) 
or to switch off the LCD display at all.  

The transmitter communicates by means two galvanically separated current 
loop  4-20mA.  Each  loop  has  two-wire  connection  and  each  loop  requires 
power  from  evaluation  device.  It  is  always  necessary  to  connect    loop  I1 
which is designed for supplying of measuring part of the device. Using the 
configuration software can be assigned to each current loop any measured 
or computed value. 

All  transmitter  setting  is performed  by  means  of the  PC  connected  via  the 
optional  SP003  communication  cable  (not  included  in  delivery).  Using 
TSensor  software  (see 

www.cometsystem.com

)  you  can  assign  to  each 

output any measured or computed value and to set its measuring range. It is 
also possible to assign both outputs to the same value (with the same range), 
if two evaluation devices are necessary to connect. The program supports 
make the adjustment of the device too. This procedure is described at file 

Calibration manual.pdf

“ which is installed commonly with the software. 

 

Device versions: 

T3110 

transmitter with cable gland for output cable connection    

T3110L 

device  version  with  watertight  male  connector  instead  of  a 
cable  gland  for  easy  connection/disconnection  of  the  output 
cable (protection IP67)  

T3110Ex 

intrinsically  safe  transmitter  for  use  in  potentially  explosive 
environments  

T3110Z

 

this  marking  is  intended  for  a  non-standard  versions  of  the 
transmitters. Description is not included in this manual.  

 

Содержание T3110

Страница 1: ...www cometsystem com Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature relative humidity and other calculated humidity values with 4 20 mA outputs...

Страница 2: ...vement of their products Manufacturer reserves the right to make technical changes to the device without previous notice Misprints reserved Manufacturer is not responsible for damages caused by using...

Страница 3: ...DEVICE INSTALLATION 7 INFO MODE 8 MODIFICATION OF DEVICE ADJUSTMENT 9 ERROR STATES OF THE DEVICE 10 TECHNICAL SUPPORT AND SERVICE 11 TECHNICAL DATA 12 MEASURED VALUES 12 CALCULATED HUMIDITY VALUES 12...

Страница 4: ...f the device Using the configuration software can be assigned to each current loop any measured or computed value All transmitter setting is performed by means of the PC connected via the optional SP0...

Страница 5: ...rective 2014 34 EU ATEX the T3110Ex transmitter conforms to European Standards EN 60079 0 2018 and EN 60079 11 2012 Transmitter is suitable for use in potentially explosive atmospheres Apparatus Group...

Страница 6: ...ice is set from the manufacturer to the following parameters value at output I1 relative humidity range 4 20 mA corresponds 0 to 100 RH value at output I2 temperature range 4 20 mA corresponds 30 to 8...

Страница 7: ...onditions for safe installation in potentially explosive environments The cables should be located as far as possible from potential interference sources It is not recommended to use the device for lo...

Страница 8: ...t corresponding to measured value on the lower line here 20 mA corresponds to 100 RH After next press of the button LCD display shows the type of value assigned to 2 output here C temperature and 2 lo...

Страница 9: ...ews of the device lid and remove the lid If device is already installed to measuring system disconnect wires from terminals connect SP003 communication cable to the PC Installed USB driver detect conn...

Страница 10: ...ity calculation of humidity is not possible due to error during temperature measurement calculation of the computed value is not possible error during measurement of temperature or relative humidity o...

Страница 11: ...T3110 09 11 Technical support and service Technical support and service is provided by distributor For contact see warranty certificate You can use discussion forum at web address www forum cometsyst...

Страница 12: ...mperature step 20 C Relative humidity Accuracy 2 5 RH from 5 to 95 RH at 23 C Measuring range 0 to 100 RH Resolution 0 1 RH Response time t90 30 s humidity step 65 RH constant temperature Calculated h...

Страница 13: ...sure Pressure for quantities calculation is stored in device memory Default value is 1013hPa and can be changed by software Accuracy 2 g kg at ambient temperature T 35 C Measuring range 0 to 995 g kg...

Страница 14: ...13 ATEX 0189X Marking ll 3G Ex ic llC T6 Gc Compliance with standards EN 60079 0 2018 and EN 60079 11 2012 Intrinsically safe parameters of current loops I1 and I2 Ui 30 V Ii 100 mA Io 22 mA Ci 0 Li...

Страница 15: ...C T3110 30 to 80 C T3110L Ambient temperature range of the housing with electronics 30 to 60 C T3110Ex Temperature operating range of the measuring end of stem 30 to 80 C Relative humidity operating...

Страница 16: ...16 IE SNC T3110 09 Dimensions T3110 T3110Ex T3110L...

Страница 17: ...value Rc Rm resistance of wires shall fulfill the condition Rc 40 x Uss V 360 T3110Ex Loop resistance value Rc Rm Rs resistance of wires shall fulfill the condition Rc 40 x Uss V 360 Intrinsically saf...

Страница 18: ...18 IE SNC T3110 09 T3110L Loop resistance value Rc Rm resistance of wires shall fulfill the condition Rc 40 x Uss V 360...

Отзывы: