instruction for the service people
23
PROBLEMS
TROUBLE SHOOTING
If the pressure at the manometer
is 0,5 bar min. and the machine starts
heating, this means that the problem
is on the installation of the steam
condense recovery.
Insufficient rinsing
a)Before checking the rinse
system check that the wash
section is operating correctly,
as poor wash results may
affect the efficiency of the rinse.
Once the efficiency of wash area
has been checked make sure that:
- the dynamic pressure of the
water supply is not less than
2bar (200 kPa).
b)the nozzles are not blocked by
limestone
c)the solenoid valves "Y10" and
is operating correctly.
d)the filter of the incoming water
is not blocked.
e)the boiler is not encrusted in any
way as to limit the water flow.
Insufficient rinse temperature
a)make sure that the temperature
of the supply is that prescribed
50/55°C.
b)make sure that the thermostat
"ST10" is adjusted to the correct
temperature.
c)make sure that the thermostats
"ST10" and "ST10A" are not faulty
d)make sure that the rinsing
nozzles have not been incorrectly
increased or replaced by another
type.