instruction for the service people
19
SETTING
Cooling of HRU
(for machines with heat recovery unit only)
Adjust the thermostat ST12, placed in the box of the heat recovery, to ensure that the air
coming out from the battery of the heat recovery unit does not exceed 35-40°C.
Torque limiter
The limiter has already been described in paragraph “SAFETY DEVICES”.
It is placed on the drive shaft and is adjusted during the commissioning of the machine.
Should new adjustments be necessary, proceed as follows:
1) Switch off the machine
2) Remove protective panel
3) Load the exit table with full dishes racks up to approx. 50 cm from the end run switch
4) Loosen the clutch by means of a hooked key until the friction plate slips, then turn the
locking nut clockwise until it succeeds in transporting the racks.
5) Adjustment is considered correct, when the drive just succeeds in transporting the total
load in second speed up to the extreme end of the exit table after pressing the START
push-button.
LOADING AND UNLOADING OF THE MACHINE
For the transportation of the machine from the delivery point to the final installation
position, use a fork lift or adequate lifting equipment used by authorised staff. Lift the
machine by its frame, taking care that any protruding parts are not damaged (discharges,
wiring etc.).
MACHINE DISMANTLING
At the end of its normal lifetime, the machine has to be taken apart according to the local
regulations in force by separating the components as follows:
??
metal parts: hood, platforms, frames, filters
??
electrical parts: motors, remote control switches, microswitches, wiring
??
plastic parts: racks, connections
??
rubber parts: tubes, sleeves
Содержание ACS122
Страница 1: ...INSTRUCTION MANUAL FOR DISHWASHING Mod ACS122 ACS151 ACS152 ACS181 ACS182 ACS201 ACS202 ACS241 ACS242 ...
Страница 2: ......
Страница 4: ...instruction for the user 4 ...
Страница 7: ...instruction for the user 7 INSTRUCTIONS FOR USE ...
Страница 26: ...ACS 122 eng 03 2003 ...