5
INSTALLATION
Note: If the unit has not been stored or move in an upright position, let it stand upright for approximately 12
hours before operation. If in doubt allow to stand.
1.
Remove the appliance from the packaging and the protective film and coatings are thoroughly removed
from all surfaces.
2.
When positioning the appliance, maintain a distance of 20cm (7 inches) between the appliance and
walls or other objects for ventilation. Increase this distance if the obstacle is a heat source.
Note: Before using the appliance for the first time, clean the shelves and interior with soapy water and rinse
thoroughly.
OPERATION
CONTROL PANEL
The control panel is located below the doors on the rear of the appliance.
TURN ON
1.
Close the door of the appliance.
2.
Connect the appliance to a mains power supply.
3.
Press the button
to turn the light On or Off as required
SET THE OPERATING TEMPERATURE
1.
Press the
button. The display will flash.
2.
Press the
or
buttons to display the required temperature.
3.
Press the
button to store the temperature.
TABLE OF CONTROLLER PARAMETERS
The operating parameters of this appliance have been preset for optimum performance and to maximize the life
of the appliance.
Display
Parameter
Preset Value
Range
E1
Lower set temperature
0°C
-20°C to 2°C
E2
Upper set temperature
12°C
2°C to 45°C
E3
Temperature buffer
4°C
1°C to 10°C
E4
Temperature buffer time delay 3 minutes
0 to 10 minutes
E5
Fixed parameter
0
DO NOT CHANGE
E6
Foxed parameter
00
DO NOT CHANGE
F1
Defrost period
25 minutes
1 to 60 minutes
F2
Defrost interval
6 hours
1 to 24 hours
F3
Defrost temperature
20°C
0°C to 22°C
F4
Centigrade/Fahrenheit
0°C
°C/°F