EQUIPMENT MANUAL FOR TB-1800
TB-1800 QE
Copyright - refer to title page
Page 43
ENU Status : 1-0-0
6 MAINTENANCE
The TB-1800 offers trouble free operation and generally does not need maintenance.
The equipment operation status can be observed remotely through OMC.
Periodic inspection of the TB-1800 equipment(s) is recommended, the recommended tasks includes:
z
Inspect and record operation status and output power of the TB-1800 from OMC or OMT.
z
Verify the direction and position of antennas. Re-align if necessary.
z
Make sure the cable gland and sealing on the RF cable connectors are not damaged.
z
Verify lightning and grounding protection is in good condition.
z
For Li-ion back-up battery, verify its state. Deeply discharged battery shall be return to Comba for
replacement.
¾
A simple procedure to check Li-ion battery: after operating for 24-hours, switch off AC power
supply. Measure and if the voltage of Li-ion battery drops below 16V within one hour, the
Li-on battery has been over-discharged.
Note: Li-ion battery status can be monitored via the OMT software if ‘Li-ion battery voltage low’ alarm is
set. If such an alarm is displayed in the OMT window, that means the Li-ion battery need to be
replaced.
End of section