EQUIPMENT MANUAL FOR TB-1800
TB-1800 QE
Copyright - refer to title page
Page 29
ENU Status : 1-0-0
OMT connection for commission and local management
A RS-232 connection is made between the PC and the equipment in two ways:
a) Without opening the enclosure, two cables are required to connect the equipment to the
computer: conversion cable is connected to the “Commissioning Port” on the bottom of the
enclosure, which is a five-pin round connector, RS-232 cable is connected to the serial port of
the computer. These two cables are connected via the DB9 connector, shown as in the
following figure.
Figure 11: Connecting local commission cable
b) With the enclosure opened, customer can connect the equipment to the PC directly via the
RS-232 port (X18) on the distribution board inside the enclosure for local commissioning.
Note: temporarily break the Li-ion battery connection before making the OMT connection.
B T S
AC220V
DC-48V/
DC+24V
ANT1
TX2/RX2
ANT2
TX1/RX1
Service
antenna 1
Service
antenna 2
TB-1800
Tower
Mounted
Booster
Figure 12: External connections of TB-1800
End of section