3. Repeat the operations described for the right-hand front brush as well.
4. To replace the brushes, refer to "ASSEMBLING THE BRUSH HEAD BODY BRUSHES" on page 19.
To clean the brush on automatic machine versions, proceed as follows:
1. Unhook the tank rotation stop lever (9) (
Fig.8
) and turn the recovery tank to its maintenance position (
Fig.9
).
2. Connect the battery connector to the machine's main system connector (
Fig.10
).
3. Rotate the recovery tank into the working position (
Fig.11
). Use the lever (9) to block rotation (
Fig.12
).
4. Sit on the driver’s seat.
5. Insert the key (10) into the main switch on the control panel. Bring the main switch to the "I" position, making a quarter turn clockwise with
the key (10) (
Fig.13
).
6. Select the "TRANSFER" program, then turn the knob (11) on the control panel (
Fig.14
) as far as icon (A) (
Fig.15
).
N.B.:
in this way, both the brush head body and the squeegee body will move to their idle position.
7. When button (12) on the control panel (
Fig.16
) is pressed for the first time, the confirmation request symbol will appear on the control display
(
Fig.17
).
8. Pressing the button (12) again will activate the brush release function.
N.B.:
Once the release sequence has been activated, it is not possible to activate other functions or move the machine.
CAUTION:
During this operation, check there are no people or objects near the brush.
9. To replace the brushes, refer to "ASSEMBLING THE BRUSH HEAD BODY BRUSHES" on page 19.