LED
flashes
Fault
Level Set conditions
Operator action
7
Motor high voltage
protection
I
Capacitor voltage has entered the
motor high voltage cutback region
defined in 4612
h
.
Reduce battery voltage
below start of motor
high voltage cutback
region.
7
Controller high voltage
protection with line
contactor open.
S
Battery voltage or capacitor
voltage is above the maximum
level allowed for the controller
with line contactor open.
Isolate controller and
investigate high
battery voltage
7
Battery voltage below
critical level for
controller.
S
Battery voltage is below the
absolute minimum voltage at
which the controller hardware is
guaranteed to operate.
Increase battery
voltage.
7
Precharge failure
VS
Capacitor voltage is less than 5V
after pre-charge operation is
complete.
Check controller
wiring to ensure there
are no short circuits
between B+ and B-.
8
Controller too hot
I
Controller has reduced power to
motor(s) below maximum specified
by user settings due to controller
over temperature.
Remove loading to
allow controller to cool
down.
8
Controller too cold
I
Controller has reduced power to
motor(s) below maximum specified
by user settings due to controller
under temperature.
Allow controller to
warm up to normal
operating temperature.
8
Motor over temperature
I
Controller has reduced power to
motor(s) below maximum specified
by user settings due to motor over
temperature.
Reduce load to motor
to allow it to cool
down.
8
Motor too cold
I
Motor thermistor reports less than
-30ºC.
Allow motor to warm
up. Check motor
thermistor.
8
Heatsink over
temperature
VS
Heatsink temperature
measurement has exceed absolute
maximum for controller and
system has powered down.
Remove loading to
allow controller to cool
down.
10
Pre-Operational
I
Controller is in pre-operational
state.
Use DriveWizard to
put controller into
operational state.
10
I/O initializing
I
Controller has not received all
configured RPDOs within 5s of
power up.
Check CANbus wiring
and PDO
configuration.
10
RPDO Timeout
I /
DI /
S
One or more RPDOs have not been
received within 3s at power up or
within 500ms during operation.
Check CANbus wiring
and PDO
configuration.
Troubleshooting
Chapter 10
10-17