background image

6700C Series

Sensor Operated Mixing Faucet

Troubleshooting Guide

Normal Operation: When power is connected, the faucet will immediately perform diagnostic function. You 
will hear a clicking sound and see lights flash. When the user’s hands are placed under the spout, the light 
will flash once and water will start to flow. Water flow will stop when hands are removed. The red indicator 
light will flash when the batteries are low. 

Turn the manual handle clockwise to increase temperature and counter-clockwise to decrease.

Problem

Possible Cause

To Diagnose

Remedy

Faucet will not turn on:

Water not turned on

Check water supply

Turn water on

Power supply failure

No light, no clicking:

• Check batteries
• Check power adapter

Reinstall or replace batteries/
Replace power adapter

Low battery

Light continues to flash

Replace batteries

Electronic PCB / Sensor is 
defective

No light, no clicking:

• Reinsert batteries
• Reattach power adapter

Replace electronic PCB

Solenoid valve is clogged

Solenoid is clicking but no water 
is coming out

Clean solenoid

In-line filter is clogged

Open clean-out trap and check 
filter screen

Clean or replace filter screen

Solenoid coil is defective

Insert new batteries or reattach 
power adapter. Light blinks but 
no solenoid is clicking

Replace solenoid coil

Flow control is clogged

Open flow control device and 
check

Celan the flow control device

Faucet will not shut off, 
has low glow, or drips:

The solenoid valve is normally closed. Turn off water and activate the faucet. If there is a clicking 
sound, the solenoid valve is dirty. If there is no clicking sound, then check the solenoid valve. If 
the faucet is dripping, clean the solenoid valve.

IMPORTANT: Periodic maintenance is required for smooth and trouble-free operation of this faucet.

For service and inquiry about available repair kits, please call Hydrotek Technical Support at (800) 922-

9883.

Care and Cleaning Instructions:

•  WARNING! Using abrasive or chemical cleaners will damage the chrome or decorative finishes. 
•  Use only soap and water to clean the finish, then wipe dry with a clean cloth. 
•  If chemical cleaners are used for other parts of the lavatory, ensure that the faucet is protected from 

potential contact from those cleaners. 

6700C Series

Sensor Operated Mixing Faucet

Troubleshooting Guide

Содержание SANI-LAV 512FAL

Страница 1: ...ds Free Floor Mount Stainless Steel Wash Station AC Models 512FAL and 512FAL 0 5 Battery Models 512FBL and 512FBL 0 5 of Domestic and Foreign Parts Columbia does not recommend use with harsh chemicals...

Страница 2: ...ontrol boxes at desired location on wall 4 Connect power line from sensor to control box 5 Attach supply tube from faucet to control box 6 Connect hot and cold water from the source to mixing check va...

Страница 3: ...mm 18 457mm 18 457mm 22 559mm 22 559mm 7 5 191mm 45 120 3048mm 20 508mm 20 508mm 40 1016mm 40 1016mm 117 2972mm 20 508mm 16 5 407mm 5 R 12 7mm 1 5 38mm 2 51mm 1 5 38mm Top 6 152 4mm 875 22mm dia holes...

Страница 4: ...4 COLUMBIA SPECIFICATIONS AC OR BATTERY POWERED 800 626 2117 columbiasinks com info columbiasinks com 2021 Columbia Products WASH STATION WITH ELECTRONIC SENSOR Leg Assembly x 18...

Страница 5: ...stration C Do not leave salt in the sink or near a saltwater environment Use a quality stainless steel cleaner and follow cleaner instructions Wipe along the grain NOT against Illustration D Things to...

Страница 6: ...Plug in Input AC 120V 60 Hz or 220V UL CSA Output DC 12V 0 8A Class 2 Power Cable Armored vandal resistant Optional Multi Unit Adapter Serves up to 8 faucets UL CSA Input AC 120V Output DC 12V 3A Batt...

Страница 7: ...e sink wall and tighten the faucet onto the sink using the O Ring 8 Washer 9 and Mounting Nut 10 Attach the 90 Degree Elbow 11 to the Supply Rod 7 USE TEFLON TAPE ONLY NO PIPE DOPE 5 Reconnect the Sen...

Страница 8: ...d In line filter is clogged Open clean out trap and check filter screen Clean or replace filter screen Solenoid coil is defective Insert new batteries or reattach power adapter Light blinks but no sol...

Страница 9: ...ing 6 Piston Piston Spring and check the Piston Sleeve for corrosion 6 Re install all parts in same order as the diagram below 7 Re install solenoid on the control box and re mount box in water line 8...

Страница 10: ...H Sw7 Sw8 Mode On Off Auto Faucet 6700C Series Sensor Operated Mixing Faucet Control Module Settings IMPORTANT Always push the Reset Button after any adjustments 1 2 3 4 5 6 7 8 Factory Preset Switch...

Отзывы: