background image

6700C Series

DC Powered Sensor Operated Mixing Faucet

Installation Instructions

ISO 9001 Certified

6700C Series

Sensor Operated Faucet

Installation Instructions

 

HYDROTEK INTERNATIONAL, INC.

5055 Forsyth Commerce Rd., Ste 124

Orlando, FL 32807

800.922.9883 (Phone)

866.670.5580 (Fax)

www.hydrotekintl.com

1.  Flow Control Device

2.  Gooseneck Spout

3.  Spout Nut

4.  Split Washer

5.  Body

6.  LED Sensor Cover

7.  Supply Rod

8.  O-Ring

9.  Washer

10.  Mounting Nut

11.  90 Degree Elbow

12.  Supply Tube

13.  Compression Fitting

14.  Solenoid Valve

15.  In-Line Filter

16.  Nylon Washer

17.  Sensor Eye Cable

18.  Control Box

19.  Power Adapter

Parts:

1.  Prior  to  installation,  thoroughly  flush  all  water  lines  and  replace 

stop washers, if required.

2.  To ensure proper operation, “DRY TEST” the faucet by plugging the 

Sensor Eye Cable (17) into the matching connector on the PC board 

inside of the Control Box (18). 

a.  AC Powered: Connect the Power Adapter (19) to the PC board 

inside of the Control Box (18), then plug the Power Adapter 

into a 120 V AC wall outlet. Place your hand in front of the 

sensor eye and listen for a clicking sound. If there is no clicking 

sound, call the factory.

b.  Battery Powered: Properly install new batteries into the battery 

holder and ensure the battery holder is connected to the PC 

board. Place your hand in front of the sensor eye and listen for 

a clicking sound. If there is no clicking sound, call the factory.

3.  After a successful “DRY TEST”, unplug the Sensor Eye Cable (17)  and 

Power Adapter (19) or battery holder from the PC board.

4.  Loosen  Flow Control Device (1) and assemble the Gooseneck 

Spout (2) using the Split Washers (4) and Spout Nut (3). Mount the 

Gooseneck Spout (2) onto the Body (5). Feed the Sensor Eye Cable 

(17) through the sink wall and tighten the faucet onto the sink using 

the  O-Ring (8),  Washer (9), and Mounting  Nut  (10).  Attach  the 

90-Degree Elbow (11) to the Supply Rod (7).

 

USE TEFLON TAPE ONLY, NO PIPE DOPE

5.  Reconnect the Sensor Eye Cable (17) and Power Adapter (19) 

connections  described  in  STEP  #2,  making  sure  the  cables  are 

seating in the Control Box (18) housing properly.

6.  Attach the Compression Fitting (13) to the Solenoid Valve (14) and 

connect it to the Elbow (11) usingn the Supply Tube (12). Insert the 

Nylon Washer (16) into the swivel nut located on the In-Line Filter 

(15)

a.  Pre-tempered  or  cold  water  only:  Use  a  union  fitting  (not 

supplied) to connect the supply line (not supplied) from the 

supply stop to the In-Line Filter (15). 

b.  Tempered water: Attach an optional Hydrotek HC-001 or HC-

003 mixing valveto the In-Line Filter (15). Connect the supply 

lines (not supplied) to the mixing valve. 

7.  Turn on water and check for leaks. Plug the Power Adapter (19) 

into  a  120V  AC  outlet  (for  AC  Powered).  Push  the  reset  button 

on the PC Board. Reinstall the cover for the Control Box (18) and 

tighten screws to ensure water resistance. Place hands in front of 

the sensor eye to activate water flow. Remove hands and the water 

should stop. If not, refer to the troubleshooting guide or call the 

factory.

8.  Periodically clean the filter element located inside the In-Line Filter 

(15).

9.  For minor adjustments, refer to the instructions located inside the 

cover of the Control Box (18).

10.  IMPORTANT: The stop valve should never be opened to the point 

where the water flow exceeds the flow capability of the fixture. The 

fixture must be able to accommodate the continuous water flow 

from the faucet in the event of a failure. Should the fixture overflow 

due to water exceeding the capability of the fixture and/or the drain 

pipe, Hydrotek will not be responsible for any damages.

6700C Series

DC Powered Sensor Operated Mixing Faucet

Installation Instructions

Содержание SANI-LAV 512FAL

Страница 1: ...ds Free Floor Mount Stainless Steel Wash Station AC Models 512FAL and 512FAL 0 5 Battery Models 512FBL and 512FBL 0 5 of Domestic and Foreign Parts Columbia does not recommend use with harsh chemicals...

Страница 2: ...ontrol boxes at desired location on wall 4 Connect power line from sensor to control box 5 Attach supply tube from faucet to control box 6 Connect hot and cold water from the source to mixing check va...

Страница 3: ...mm 18 457mm 18 457mm 22 559mm 22 559mm 7 5 191mm 45 120 3048mm 20 508mm 20 508mm 40 1016mm 40 1016mm 117 2972mm 20 508mm 16 5 407mm 5 R 12 7mm 1 5 38mm 2 51mm 1 5 38mm Top 6 152 4mm 875 22mm dia holes...

Страница 4: ...4 COLUMBIA SPECIFICATIONS AC OR BATTERY POWERED 800 626 2117 columbiasinks com info columbiasinks com 2021 Columbia Products WASH STATION WITH ELECTRONIC SENSOR Leg Assembly x 18...

Страница 5: ...stration C Do not leave salt in the sink or near a saltwater environment Use a quality stainless steel cleaner and follow cleaner instructions Wipe along the grain NOT against Illustration D Things to...

Страница 6: ...Plug in Input AC 120V 60 Hz or 220V UL CSA Output DC 12V 0 8A Class 2 Power Cable Armored vandal resistant Optional Multi Unit Adapter Serves up to 8 faucets UL CSA Input AC 120V Output DC 12V 3A Batt...

Страница 7: ...e sink wall and tighten the faucet onto the sink using the O Ring 8 Washer 9 and Mounting Nut 10 Attach the 90 Degree Elbow 11 to the Supply Rod 7 USE TEFLON TAPE ONLY NO PIPE DOPE 5 Reconnect the Sen...

Страница 8: ...d In line filter is clogged Open clean out trap and check filter screen Clean or replace filter screen Solenoid coil is defective Insert new batteries or reattach power adapter Light blinks but no sol...