6
COLUMBIA SPECIFICATIONS
800.626.2117
columbiasinks.com
info@
columbiasinks.com
©2021 Columbia Products
SENSOR FAUCETS
SANI-LAV Sensor Faucets
Wall Mounted AC and Battery Powered
Meets ANSI/ASME A112.18.1 M-1989
Operation
1. A continuous, invisible beam is emitted from the sensor.
2. The faucet is activated by placing hands under the spout within the effective
range of the beam. Water starts to flow immediately for as long as the user’s
hands remain in the sensor range.
3. When hands are removed, the water flow stops. The sensor will automatically
reset and be ready for the next user.
4. In the battery powered version, a flashing red light will indicate a low battery
condition.
Specifications
Faucet Construction
Solid brass, chrome plated
Control Circuit
Solid state, AC or battery, switchable
– Auto. Time-out
Preset at 20 seconds and adjustable to 10,
30, or 60 seconds
– Line Purge (request only)
2 minute run every 12 hours
or 24 hours
– Scrub Mode Delay (request only) 60, 120, 180 seconds
– Sensor Range
Preset and adjustable
– Shut-off Delay
Presets and adjustable from 1-8 seconds
Control Cable
Armored, vandal resistant
Solenoid Valve
6V DC, normally closed
– Wattage: 0.4W (idle), 5W (in use)
– Operating Pressure: 5 psi to 125 psi
Flow Control
2.0 or 0.5 GPM, Laminar Flow Control
AC Mode
Power Adapter
– Standard Plug-in
Input AC 120V 60 Hz or 220V
– (UL/CSA)
Output DC 12V, 0.8A/Class 2
Power Cable
Armored, vandal resistant
– Optional Multi-Unit Adapter
Serves up to 8 faucets
– (UL/CSA)
Input AC 120V, Output DC 12V, 3A
Battery Mode
Battery Powered Models
(4) AA Alkaline Batteries
Battery Service Life
400,000 on/off cycles, up to 4 years
Package Includes
(1) Faucet with electronic sensor
(1) Control box w/6V DC solenoid
(1) 12V DC plug-in power adaptor (H-6700C, -DC, -LR and -LRDC only)
(1) In-line filter with clean-out trap
(1) 18” Flex, S.S. supply tube, 3/8”(1) 6” Gooseneck Spout
(1) Mounting hardware
(1) 2.0 GPM Flow Control(4) AA Alkaline batteries (HB-6700C, -DC, -LR, -LRDC only)
(1) Battery holder (HB-6700C, -DC, -LR, -LRDC only)
Dimensions
– Base Width (Outside Measurement)
2-1/4”
– Base Depth
2-1/2”
– Faucet Height (Aerator to Base)
8-3/4”
– Faucet Height Overall
12-3/4”
– Depth (Center of Aerator to Center of Faucet Base)
5-3/8”
– Mounting Bolt Length
1-7/16”
– Mounting Bolt Pattern
Single-hole mount
Optional Variations and Accessories
– 0.35, 0.5, 1.5, 2.2 GPM Laminar Flow
– HC-010 Multi-Unit Voltage Adapter (AC Powered Only) - 8 units
– HC-0104 Multi-Unit Voltage Adapter (AC Powered Only) - 4 units
– HC-001 Mixing/Check Valve (Mechanical)
– HBL-04-LR Thermostatic Mixing Valve with Checks (Low Lead)
– 8” deep Gooseneck and 6” or 8” Swing Swing SpoutModel
Model
Sensor Type
Flow-Rate
ES2RL
AC Powered
Standard 2.0 GPM
ES2RL-0.5
AC Powered
Low-Flow 0.5 GPM
Model
Sensor Type
Flow-Rate
ESB2RL
Battery Powered
Standard 2.0 GPM
ESB2RL-0.5 Battery Powered
Low-Flow 0.5 GPM
ADA Compliant