background image

2

COLUMBIA  SPECIFICATIONS  

AC OR BATTERY POWERED

800.626.2117   

columbiasinks.com

   info@

columbiasinks.com

©2021 Columbia Products

WASH STATION WITH ELECTRONIC SENSOR

Parts List

 (1) Floor mount wash station
 (1) Leg assembly set
 (18) Nuts, bolts and washers for leg assembly
 (8) Nuts and washers for connecting sink to leg assembly
 (6) AC or Battery powered sensor faucet assembly
 (6) Mixing check valve 
 (3) Strainer assembly with basket

Installation Instructions

Step 1 

1. 2 and 3-Person models require leg assembly. 
2. Place wash station sink on leg assembly and secure with hardware (provided).
3. Establish sink location.
4. Mark the floor where the four holes are at the base as shown in illustration A. 
5. Drill holes as required for mounting hardware. (Hardware not included). 

Step 2

 

1. Install strainer assembly.
2. Install faucets to the sink following the instructions provided with sensor unit.
3. Attach supply tube with elbow to back of faucet.
4. Install mixing check valve and compression fitting to control box of each sensor faucet.

Step 3

 

1. Secure wash station to floor.
2. Connect waste line to strainer assembly (s).
3. Mount sensor control boxes at desired location on wall.
4. Connect power line from sensor to control box.
5. Attach supply tube from faucet to control box.
6. Connect hot and cold water from the source to mixing check valve (s).
7.  Remove aerator from the spout assemblies and flush water system. (see step 7 sensor 

installation instructions)

8. Check connections for leaks.
9. Replace aerator onto the spout (s).

Step 4

 

1. Seal gap between bowl and leg assembly as shown in illustration B.
2. We recommend sealing top of backsplash to wall if applicable as shown in illustration C.

WARNING:

 This product can expose you to chemicals including Chromium (hexavalent compounds), 

Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects 
or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov

.

NOTE

Lead content originates from Brass components in valves and faucets and is certified under 

NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.

Notice for California Consumers

Go to 

columbiasinks.com

 

for more information on replacement parts and installation videos.

Tools Required

 Tape measure
 Adjustable wrench
 Drill motor and drill bits
 Pipe wrench
 Level
 Safety glasses
 Screw drivers: phillips and standard
 Pencil
 Socket wrench

Illustration A

Illustration B

Illustration C

Содержание SANI-LAV 512FAL

Страница 1: ...ds Free Floor Mount Stainless Steel Wash Station AC Models 512FAL and 512FAL 0 5 Battery Models 512FBL and 512FBL 0 5 of Domestic and Foreign Parts Columbia does not recommend use with harsh chemicals...

Страница 2: ...ontrol boxes at desired location on wall 4 Connect power line from sensor to control box 5 Attach supply tube from faucet to control box 6 Connect hot and cold water from the source to mixing check va...

Страница 3: ...mm 18 457mm 18 457mm 22 559mm 22 559mm 7 5 191mm 45 120 3048mm 20 508mm 20 508mm 40 1016mm 40 1016mm 117 2972mm 20 508mm 16 5 407mm 5 R 12 7mm 1 5 38mm 2 51mm 1 5 38mm Top 6 152 4mm 875 22mm dia holes...

Страница 4: ...4 COLUMBIA SPECIFICATIONS AC OR BATTERY POWERED 800 626 2117 columbiasinks com info columbiasinks com 2021 Columbia Products WASH STATION WITH ELECTRONIC SENSOR Leg Assembly x 18...

Страница 5: ...stration C Do not leave salt in the sink or near a saltwater environment Use a quality stainless steel cleaner and follow cleaner instructions Wipe along the grain NOT against Illustration D Things to...

Страница 6: ...Plug in Input AC 120V 60 Hz or 220V UL CSA Output DC 12V 0 8A Class 2 Power Cable Armored vandal resistant Optional Multi Unit Adapter Serves up to 8 faucets UL CSA Input AC 120V Output DC 12V 3A Batt...

Страница 7: ...e sink wall and tighten the faucet onto the sink using the O Ring 8 Washer 9 and Mounting Nut 10 Attach the 90 Degree Elbow 11 to the Supply Rod 7 USE TEFLON TAPE ONLY NO PIPE DOPE 5 Reconnect the Sen...

Страница 8: ...d In line filter is clogged Open clean out trap and check filter screen Clean or replace filter screen Solenoid coil is defective Insert new batteries or reattach power adapter Light blinks but no sol...

Страница 9: ...ing 6 Piston Piston Spring and check the Piston Sleeve for corrosion 6 Re install all parts in same order as the diagram below 7 Re install solenoid on the control box and re mount box in water line 8...

Страница 10: ...H Sw7 Sw8 Mode On Off Auto Faucet 6700C Series Sensor Operated Mixing Faucet Control Module Settings IMPORTANT Always push the Reset Button after any adjustments 1 2 3 4 5 6 7 8 Factory Preset Switch...