4 Position the machine at a minimum distance
of 1 m. from the surrounding walls and at a
distance of not less than 1.5 m. from the
ceiling in order not to compromise the proper
operation and cooling of the pump unit
(Fig. 39).
5 The models with the internal combustion
engine must be placed outside at a minimum
distance of 1 m from buildings and machines
(Fig. 40).
6 Make sure that the machine is in a well-lit area, so that each detail can be clearly made out (especially
the writing on the plates).
Add artificial lighting to the area if the natural lighting is not suffieint for the requirements mentioned
6.2.1
Connecting the extension for the air intake
6.2
C o n n e c t i o n s
For models run on electricity, if the machine should be placed in a location without the ventilation
characteristics described in the previous paragraph, an extension must be installed to have an intake
of air from outside or from a place with the ventilation characteristics described.
40
Installation
Содержание MCH 13/DH
Страница 93: ...93 13 2 Electricals diagrams Machine diagrams...
Страница 94: ...94 Machine diagrams...
Страница 100: ...100 126 124 125 123 017 018 015 019 021 002 002 A 022 007 038 037 039 043 043 A 190 191 024 Spare parts Cylinders unit...
Страница 106: ...106 153 152 156 155 154 158 097 157 159 160 198 188 187 189 Spare parts Filtering system...
Страница 110: ...110 MCH 13 16 ETC Spare parts 006 007 008 009 005 012 013 010 011 002 001 003 004...
Страница 112: ...112 MCH 13 16 ET Spare parts 006 007 008 009 005 012 013 010 011 002 001 003 004 015 014 016...
Страница 114: ...114 MCH 8 EM Spare parts 006 007 008 009 017 012 013 010 011 002 001 003 004 015 014 016...
Страница 116: ...116 MCH 13 16 SH Spare parts 006 007 008 009 018 012 013 019 020 002 001 003 004...
Страница 118: ...118 MCH 13 16 DY Spare parts 015 014 003 004 002 001 022 023 009 016 007 008 021 006 012 013...