Service Menu VIBA X.30 

 

 

 

2021-05-05  Seite 17/21

 

5.6.2

 

TEST ENDPOS 

TEST ENDPOS 

900 

OPEN 

CLAMP 

EDIT 

 
 

EDIT ENDPOS 

900 

 

 
 

Set mixing unit end stop. 

 

OPEN 

=   Test upper end stop 

CLAMP 

=  Test lower end stop 

EDIT 

=  Modify ENDPOS parameter 

 
The mixing unit is opened and closed via a DC motor the power 
consumption of which is monitored. 

When the end stop is reached the power drawn by the motor 
exceeds the set value of the current threshold (ENDPOS) and the 
clamping motor is shut off. 

The factory set parameter for the end stop has been selected so 
that the mixing unit arrives directly at the end position without a 
prior switching off. 

Before modifying the parameter check whether the threaded 
spindles are dirty or damaged. If necessary, clean and apply grease 
to the spindles as described in the operating instructions.

 

A larger value for the DC-MOT ENDPOS means a higher current 
intake and thereby a larger force of the clamping motor.  

The value must not be set too high, otherwise the threaded spindle 
could jam. 

 

IMPORTANT: 

The ENDPOS parameter does not influence the clamping force; 
the clamping force is set in the menu item 5.5 SET CLAMP FORCE 

 
 

Содержание VIROneo VIBA X.30

Страница 1: ...2 ENTER CODE 3 2 3 CODE ENTRY ERROR 3 3 NAVIGATION IN SERVICE MENU 4 3 1 KEYS FUNCTION 4 4 MENU STRUCTURE 5 5 MENU DESCRIPTION 8 5 1 TEST 8 5 2 SET TIME VIBA X 30 VIRONEO AND VIBA X 30 S 9 5 3 EDIT TI...

Страница 2: ...ich various functions are tested and machine specific parameters may be modified Please carefully read the operating instructions provided with the machine prior to all work in the service menu and pa...

Страница 3: ...chine on via the main switch After a short period ENTER CODE will appear on the display ENTER CODE CODE 0000 ENTER WITH E Button E Button III 2 2 Enter code Enter the code 3970 on the keypad to activa...

Страница 4: ...ST D LOCK DOOR FUSE E STOP F RUN MOTOR EDIT TIME T1 T2 T3 Submenu TEST FREERUN min 0 405mm actual 0000 10000 max 0 CLOSE OPEN Functions CLOSE OPEN 3 1 Keys function Key for DOOR Opening of the door Ke...

Страница 5: ...tructure TEST D LOCK DOOR FUSE E STOP F RUN MOTOR VIBA X 30 VIBA X 30 S VIBA X 30 V SET TIME 0 30 1 00 2 00 T1 T2 T3 EDIT TIMELINE PGM1 PGM2 PGM3 SET BUTTONS T1 T2 T3 I II III SELECT HEIGHT 100mm 220m...

Страница 6: ...BA X 30 2021 05 05 Seite 6 21 SET CLAMP PAR 900 F RUN ENDPOS ICC SET DOOR YES NO YES DOOR START UCLMP SET LANGUAGE ENGLISH Press E to quit SELECT STE TIME DATE 10 15 28 01 05 2019 OPERATING HOURS HOUR...

Страница 7: ...Service Menu VIBA X 30 2021 05 05 Seite 7 21 OPERATING CYCLES CYCLES 00064021 NEXT ENTER S N S N 00980059 NEXT SAVE CHANGES SAVE UNDO RESET...

Страница 8: ...RUN TEST FREERUN MOTOR MOTOR TEST 5 1 1 TEST FREERUN TEST FREERUN min 0 410mm actual 0000 10000 max 0 CLOSE OPEN The function of the clamping motor is tested in the TEST FREERUN submenu CLOSE Close mi...

Страница 9: ...successful clamping routine 5 2 SET TIME VIBA X 30 VIROneo and VIBA X 30 S SET TIME T1 T2 T3 EDIT TIME 1 00 30 min The mixing times 1 3 are preset in SET TIME main menu T1 Set mix time 1 T2 Set mix t...

Страница 10: ...ity of the mixing materials 5 3 1 EDIT PGM EDIT PGM 1 Total 0 40 Time 0 0 10 Speed 0 40 TIME SPEED The mix programme is defined in the EDIT PGM submenu Total PGM1 total time display Time 0 Time displa...

Страница 11: ...programmed in this way IMPORTANT A mixing speed which is too high can cause damage to the mixing can Check the suitability of the mixing can through a mix test after each speed modification 5 4 SET B...

Страница 12: ...AMP FORCE SET CLAMP FORCE 500 800 1200 LOW MED HIGH Three clamping pressures can be set in the SET CLAMP FORCE menu With this small medium and cans will always be maintained with an adapted clamp forc...

Страница 13: ...ust be smaller than the HEIGHT LOW value set The clamping routine is started via the CLAMP function The current opening of the mixing unit can be read in display together with the current value of the...

Страница 14: ...er than the HEIGHT LOW and lower than the HEIGHT HIGH value set The clamping routine is started via the CLAMP function The current opening of the mixing unit can be read in display together with the c...

Страница 15: ...must be larger than the HEIGHT HIGH value set The clamping routine is started via the CLAMP function The current opening of the mixing unit can be read in display together with the current value of th...

Страница 16: ...function of the clamping motor is tested in the TEST FREERUN submenu CLOSE Close mixing unit OPEN Open mixing unit The clamping motor runs for the amount of time the key is held down The minimum curr...

Страница 17: ...The factory set parameter for the end stop has been selected so that the mixing unit arrives directly at the end position without a prior switching off Before modifying the parameter check whether th...

Страница 18: ...nt The parameter of the intelligent current monitoring was determined in an intensive series of tests and are optimally suited for most of the commonly used cans available on the market Any modificati...

Страница 19: ...GE ENGLISH Press E to quit SELECT Language setting for the main menu SELECT Language selection The service menu language cannot be modified 5 9 SET TIME DATE SET TIME DATE 10 15 28 01 05 2019 Setting...

Страница 20: ...66 Enter the serial number of the VIBA Increase value Decrease value Next digit The serial number of VIBA is indicated on the nameplate If the smartCONNECT functionality is available the VIBA identifi...

Страница 21: ...Service Menu VIBA X 30 2021 05 05 Seite 21 21 6 Schematic diagram...

Отзывы: