Collomix GmbH
Shaker
VIBA X.30
D-85080 Gaimersheim
Version 1.0-20
9
3.5
Safety-relevant components
The machine is equipped with various safety devices. These help to avoid dangers to body and life
through electrical and mechanical impacts on the persons working with the Shaker and they help to
limit any material damages to the system.
Do not bypass, remove, or render ineffective the safety equipment.
Do not operate the system if the safety equipment is not complete or fully functional.
Closed housing
The housing, which can only be opened with tools, forms a fixed, separating safety device.
Therefore, do not operate the machine if the rear panel or other covers are open; Unplug mains
before opening this, to avoid a start
Machine door with interlocking device
The door forms a locking, separating unit with interlocking device. The machine cannot be started
when the door is open. The door is only releases after the mixing process has ended and the mixing
vessel is released. Never operate the machine if the machine door is damaged.
EMERGENCY STOP Switch
In emergencies, the EMERGENCY STOP function is used to stop the running machine if necessary.
3.6
Residual Risks
If all precautions are taken, there may be obvious residual risks. Adhering to the safety instructions,
the designated use, and the operating instructions can reduce residual risks!
4.
Equipment Description
The Shaker is a stationary mixing device for closed, tightly closing, round, angular, and oval vessels
made of metal or plastic. It is suitable for mixing colours, colour concentrates, building and industrial
lacquers, and other materials with low viscosity.
The area of application ranges from the colour wholesale to retail trade, the lacquer and chemical
industry to any similar areas. This mixing device is especially suited as system component for colour
dosing systems.
The container is automatically clamped into the machine and the substance is mixed by linear
inertial forces using an alternating orbital shaking motion.
The necessary mixing time and the suitability of the containers must be determined by mixing trials
prior to use.