9.

 

Accessories 

The following accessories are available for the device: 

 

Part 

Article no.: 

Cover insert 20 mm (set has 5 pieces each) 

74088 

Cover insert 5 mm (set has 5 pieces each) 

74136 

Handle fixation 

64447 

Mobilux EP2 100 g 

61299 

 

Spare parts are available at www.collomix.de. 

10.

 

Storage, disposal 

 

10.1

 

Storage 

The storage area should be cool and dry in order to prevent corrosion on the individual parts of the 

machine.  

The room temperature of the storage area must be constantly above freezing. 

 

 

Package the device to prevent any damages through outside impacts during storage.  

 

If necessary, use cardboard and other packaging material. 

 

Secure the machine against unintentional tilting and instability. 

 

10.2

 

Disposal 

The transport package is made of recyclable material. Please dispose this material accordingly. 
At the end of the useful life, the machine must be properly disposed to return the used raw 

materials to the recycling loop. Please contact the manufacturer directly for any questions 

concerning disposal. 
 

Содержание VIBA X.30

Страница 1: ...Version 1 0 20 Instructions Shaker VIBA X 30 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch...

Страница 2: ...Shaker VIBA X 30 Collomix GmbH D 85080 Gaimersheim 2 Version 1 0 20...

Страница 3: ...tent 10 5 2 Set up the equipment 10 5 3 Mains connection 10 5 4 Trial run 11 5 5 Transport 11 5 6 Attach transport lock 11 6 Operation 12 6 1 Switching on the machine 12 6 2 Load a container 12 6 3 St...

Страница 4: ...Layout Drawings 1 1 Machine components Machine components 1 Power supply and AC fuse 6 EMERGENCY STOP Switch 2 Mixing table 7 Control unit 3 Clamping plate 8 Door 4 Manual door release 9 Loading shel...

Страница 5: ...eim Version 1 0 20 5 1 2 Operating and display components Button for DOOR OPEN door Button E OPEN the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Button...

Страница 6: ...ttention to the corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measu...

Страница 7: ...Instructions before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent owners 3 1 General Safety In...

Страница 8: ...e obvious with obvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unaut...

Страница 9: ...xing vessel is released Never operate the machine if the machine door is damaged EMERGENCY STOP Switch In emergencies the EMERGENCY STOP function is used to stop the running machine if necessary 3 6 R...

Страница 10: ...he permissible load of the floor Do not operate the machine on the shipping pallet or on any other unsuitable sub surfaces When setting up make sure there is enough working space in front of the machi...

Страница 11: ...ont side of the housing These transport rollers allow to move the machine over short distances in an ergonomically user friendly manner The door must be opened for the machine to be handled safely dur...

Страница 12: ...the mixing vessels To place the container proceed as follows Unlock and open the door by pushing the DOOR button To adjust the mixing unit to the height of the container use the E Button to raise the...

Страница 13: ...n the machine is not in use the door should be kept closed When done working switch the machine off at the mains switch 1 6 6 EMERGENCY STOP switch In dangerous situations the machine can be turned of...

Страница 14: ...e power cord plug to the EMERGENCY STOP button E025 Door unlocked Door does not engage Check the door lock E030 Did not find the container No mixing container is placed Place mixing container Mixing c...

Страница 15: ...y pulling out the mains plug Never use the manually door unlocking device whilst the mixing unit is turning 7 3 Fuses on the device 7 3 1 Device fuse If line voltage is available but the power button...

Страница 16: ...ed personnel may carry out maintenance and repair work Use only original replacement parts 8 2 1 Annual maintenance Clean the threaded spindles and lubricate with Mobilux EP2 Check the outer flange be...

Страница 17: ...rosion on the individual parts of the machine The room temperature of the storage area must be constantly above freezing Package the device to prevent any damages through outside impacts during storag...

Страница 18: ...apeed mixing unit 660 1 min 690 1 min 710 1 min Variable speed no no 4 intervals speeds Maximum mixing weight 40kg 40kg 40kg Container height 50 400mm 50 400mm 50 400mm Max container footprint w x d...

Страница 19: ...Collomix GmbH Shaker VIBA X 30 D 85080 Gaimersheim Version 1 0 20 19...

Страница 20: ...request technical information from Collomix GmbH Abt Technische Entwicklung Daimlerstr 9 85080 Gaimersheim Deutschland Gaimersheim 31 08 2019 Alexander Essing Managing Director Manufacturer Collomix...

Страница 21: ...Collomix GmbH Shaker VIBA X 30 D 85080 Gaimersheim Version 1 0 20 21 Collomix GmbH Daimlerstr 9 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de...

Отзывы: