4.2 Cabling
Electromagnetic interferences can lead to non repeatable and not obvious errors while labelling.
Often misplaced layout of the cabling, RMI and ESD interferences disturb the labelling. Because
of this the following rules must be observed for the cabling:
Separated mains and signal cables
Use shielded cables
All units must be grounded
Connect only devices which meet the RMI standards
Use power filtering units in interfered environments and interfered mains supplies
4.3 Setting up
The setting up must be done carefully by trained personnel. The following items must be
observed:
Visual control of the control unit
Are all electrical and mechanical units correctly attached ?
Are all connectors accessible ?
Connect the monitor to mains and switch it on
Is the display illuminated ?
Does the startup message appear ?
Turn off the monitor and unplug it from mains
Set up the winder and unwinder and connect it to the connector box
Are the jumpers inside of the winders set correctly ?
Attach the goods scanner signals to the DISPENSER connector
Connect the monitor to the mains voltage an turn it on
Do the winder turn the right way ?
Turn off the monitor and unplug it from mains
Connect the remaining units to the connector box of the Collamat
®
Connect the monitor to the mains voltage and turn it on
Do the peripheral units work OK ?
Turn off the monitor and unplug it from mains
Attach the motorcable
Connect the monitor to the mains voltage and turn it on
Does the motor work in the MOTORTEST-menu ?
Is the turning direction OK ?
Thread the paperweb and adjust the label scanner
Dispense a label by the control panel
Is it dispensed correctly ?
Connect the goods scanners (and possible incremental encoder)
Dispense a label by the goods scanner
Watch to the error messages on the display