4.1 Electrical connection
4.1.1 The connector box 9100
The signals of the C9100 monitor are fed in one cable to the connector box on the labeller. There
all electrical modules of the labeller with the exception of the stepper motor are connected. The
following Figure 14 shows the position of the connector terminals in the connector box. On the
connector p.c.board the wire colors are marked with the numbers of the resistor color code.
These colors are valid for Collamat Stralforsperipherals. The connection cables of the modules
are fed through the lateral conduit glands.
Figure 14: Connector print
4.1.2 Fuse F1, 5A slow blowing
Fuse F1 protects the 24V power supply of the winders from short-circuit and overload. If one or
both winders are dead, first check this fuse.
GND
LLO
+12V
GND
+24V
GND
RWF
+12V
GND
+24V
F1 5AT
GND
LSC
+12V
TCY
+12V
GND
FLAP
+24V
GND
FEED
R E A D Y
+12V
GND
TUNIT
+12V
1
9
5
4
5
1
9
5
1
9
5
6
1
1
9
5
6
1
Rewinder
Rewinder Full
Unwinder
Label Low Sensor
Label Scanner
Traction Unit
1: brn/bn
2: red/rt
3: org/og
4: yel/gb
5: grn/gn
6: blu/bu
7: vio/vi
8: gry/gu
9: wht/ws
0: blk/sw
5999.554-01A 16.08.2001 WM