SMARTHUB 

 

 

 

 

2.3.

 

Electrical Installation (wiring)

 

 

Principal Signals Electrical Circuit Diagram 
 

 

 
2.4.

 

Signals Control  
Sealed (IP certified), the SMARTHUB Unit is powered by a 24VDC from the CNC 
machine electric cabinet, providing signals in discrete control mode (connected 
to PLC I/O's), or optionally send data packs via RS232 serial communication.  
 

IN

STAL

LATI

ON

 

Содержание SMARTHUB

Страница 1: ...1 SMARTHUB SMARTHUB Device Monitoring Unit USER MANUAL...

Страница 2: ...UB Case Contents 1 9 Display Tablet 1 10 SMARTHUB APP 1 11 HSM Jet Spindle 2 INSTALLATION 2 1 System Requirements 2 2 Mechanical Installation 2 3 Electrical Installation wiring 2 4 Signals Control 2 4...

Страница 3: ...d to eliminate the interference by one or more of the following measures Re orient or re locate the receiving antenna Increase the distance between the device and the receiver Connect the device to an...

Страница 4: ...ny accidents by observing the following precautions Review the safety instructions of the manufacturer and all organizations responsible for the prevention of accidents Ensure the Following The work a...

Страница 5: ...machine PLC via protected electric wire cable SMARTHUB communicates directly with the machine PLC via protected electric cable The SMARTHUB relays data signals warnings and alarms to the Tablet Displa...

Страница 6: ...S Low RSSI Low Battery High Low Speed Limit Exceeded Spindle Speed 0 Power ON 1 8 SMARTHUB Case Contents One SMARTHUB Unit UL Cable one meter male Amphenol connector at the SMARTHUB end stripped for w...

Страница 7: ...r battery levels signal strength and spindle working hours Up to 4 spindles operating simultaneously Warnings and alarms Low high RPM limits Manual programming o Adjustable low high speed limits o Cut...

Страница 8: ...tHUB should be mounted inside the machine workpiece processing cabinet The back side of SMARTHUB unit has 4 standard M5 threads to interface with a mounting bracket not supplied or cabinet wall For th...

Страница 9: ...Circuit Diagram 2 4 Signals Control Sealed IP certified the SMARTHUB Unit is powered by a 24VDC from the CNC machine electric cabinet providing signals in discrete control mode connected to PLC I O s...

Страница 10: ...Signal is high when battery level is low signal is low when the spindle stops ZERO RPM Spindle is stopped may be used to control machine door latch safety 1 when power is on and spindle speed 0 HIGH...

Страница 11: ...le performing a self test procedure GREEN LED stays lit permanently as long as the device is powered BLUE LED lights up when the Bluetooth module is ON and functioning properly YELLOW LED lights up wh...

Страница 12: ...g should show 0V Low battery WHITE wire Default state is LOW Touch WHITE wire with multi meter RED point Reading should show 0V Zero RPM GREY wire Default state is HIGH Touch GREY wire with multi mete...

Страница 13: ...7 Post Installation Procedures SMARTHUB is designed to operate automatically in the presence of an RF transmission signal from a paired device spindle 2 8 Operating in Multiple Machines Multiple SMART...

Страница 14: ...Cutting Tool Description of cutting tool 4 Device SN Serial number of the spindle 5 Model Spindle model selected from drop down list 6 Machine Name of the machine operating the spindle 7 Speed Limit...

Страница 15: ...de of the Tag 3 Model Sensor model 4 Machine Name of the machine 5 Tool Type of tool 6 Position Position of the spindle sensor in the tool magazine 7 Work Time Total spindle work time hours 8 RSSI Sig...

Страница 16: ...n 4 Resources Tap to view support documents and help videos 5 Settings Tap to view or update system settings 6 Active Spindle Tap to display active spindle rotation speed charts 7 Active Spindle Displ...

Страница 17: ...he upper speed limit 5 Lower Speed Limit Dashed line represents the lower speed limit 6 Warning Alert Icon appears to indicate an active warning or alert 7 Battery Status Battery value Less than 10 ac...

Страница 18: ...id residue and easily visible Recommended Operating Environment Temperature Range 0 50 C Storage Conditions The SMARTHUB unit must be stored in conditions meeting the following requirements o Sheltere...

Страница 19: ...tion 1 Stays as visual warning on screen until the operator acknowledges it Option 2 Stop cycle until machine operator checks what is wrong Why is the Low Battery Signal warning always lit The low bat...

Страница 20: ...hine PLC regardless of the presence of the tablet The tablet is a must for binding the spindles to the SmartHUB and viewing the real time data What will happen if two SmartHUB units operate close to o...

Страница 21: ...ritten claim form with an explanation of the malfunction inclusion of the unit serial no and a copy of the product invoice The manufacturer s liability under this warranty shall be limited to the repa...

Страница 22: ...ntioned restriction terms as equally applied and specified for the SMARTHUB Unit Warranty Frame This warranty document supersedes all and any previous warrant policy information published by the manuf...

Страница 23: ...buyer s non compliance with applicable laws regulations codes or by laws and standard industry practices Transfer of Warranty The SMARTHUB unit is only covered under warranty to the original buyer of...

Страница 24: ...24 SMARTHUB SMARTHUB Device Monitoring Unit USER MANUAL Colibri SH UM001 11 2016...

Отзывы: