24
25
WARNING
Do not use the applicator body or handle for leverage when tightening the the blast
hose to the applicator. Always use two wrenches to prevent damaging the applicator and fittings.
WARNING
Do not tape, tie, or bind the blast hose and the control cable. The blast hose and
control cable are designed and tested to prevent cracking and damage. Constraining the design
flexibility may void the control cable and blast hose warranty.
4. Attach a nozzle to the applicator.
5.
Attach the ground reel to the article that is being blasted.
a.
Pull out the ground reel to the distance needed to attach to the material being
blasted.
b. Relax the ground cable and the ground line will lock into position.
c.
To reel the ground line back in, pull the ground line until it begins to spool back in
without locking. Do not let go of the ground line, feed it back into the spool until the
line is completely reeled back in.
Figure 7: Static Ground Reel
6.
7.
Loop the whip check around the air supply hose as illustrated and attach the air supply hose
to the front of the PLT 60.
CAUTION
When connecting the air supply hose to the blaster, always run the hose
through the choker of the whip check in case of accidental disconnect
Figure 8: Whip Check
8. Attach the air supply hose to the front of the PCS 60.
Maximum air supply pressure is 145 psi (10 bar)
9. Turn the air supply on and allow the air hose to pressurize.
The PCS 60 automatically bleeds pressure when the e-stop is engaged,
the safety grate is open, the unit is powered off, and/or is disconnected
from its power source
10.
Once the PCS 60 is set up, go to “Starting the PCS 60” on page 27.
Содержание AERO 2 PCS 60
Страница 1: ...Original Instructions English 2202060730 REV D PCS 60 Operator Manual...