Shutting Down the PCS 60
Follow the instructions below to shut down the PCS 60:
Always remove any remaining dry ice from the hopper if shutting down
the PCS 60 for more than 15 minutes to prevent the internal mechanics
and/or nozzle from freezing.
1. Using a plastic scoop, remove any unused ice from the hopper then close the lid.
CAUTION
Be careful to avoid coming into contact with the doser at the bottom of the
hopper
2. On the applicator:
a.
Press the air button (I) to activate (blue light on).
b. Pull the trigger to blast for 10 seconds.
c.
After blasting, press the air button (I) again to deactivate (blue light off). This should
also deactivate the applicator.
d. Remove nozzle from applicator
CAUTION
Do not touch nozzle with bare hands during or immediately after
use. Always wear protective gloves
3.
On the control panel, press the power button to turn the PCS 60 OFF.
4.
Turn off the compressed air supply. The PCS 60 will automatically bleed any remaining
pressure.
There is no need to bleed the air pressure from the PCS 60. The PCS 60
automatically bleeds air pressure during proper shut down of the PCS
60. It also automatically bleeds for approximately two seconds every 30
minutes of trigger time during operation.
5.
When all the air pressure is bled off, disconnect the air supply hose from the PCS 60.
6.
Unplug the power cord from the PCS 60 by depressing the tangs on the cord collar.
7.
If transporting the PCS 60 to a different location, disconnect all cables and hoses from the
PCS 60 first and stow them on retractable hooks.
8.
If storing the PCS 60, disconnect all cables and hoses and stow them on retractable hooks.
Store the PCS 60 in a dry space free of dirt and debris. Keep out of direct sunlight.