27. Sensors and overheating thermostats
27
Service
manual
487 0329 21
27.4
Outlet air - Overheating thermostat
Function
The outlet air overheating thermostat is located in the air flow path between the
secondary lint screen and the blower.
To access the assembly, remove the blower from the rear of the dryer (see section 30).
The overheating thermostat ensures that the dryer does not overheat during program
operation.
The thermostat opens automatically and has to be reset manually.
1. Disconnect the power supply.
After this the thermostat can either be:
Reset from the front of the dryer
2a. Pull out lint drawer A.
3a. Dismount grille B. The thermostat can now be reset manually by pressing on the tab
on the back of the holder.
Reset from the back of the dryer
2b. By dismounting the blower assembly the thermostat can be reset.
Error code
The following error code is related to this section.
E08
Refer to section 12 for more information.
A
B
Содержание T3300S
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...2 Technical data 2 Service manual 487 0329 21 2 4 ...
Страница 11: ...487 0329 21 3 1 3 Description of principal components 3 Service manual Contents Description 3 2 ...
Страница 20: ...11 Periodic maintenance 11 Service manual 487 0329 21 11 8 ...
Страница 40: ...12 Error codes 12 Service manual 487 0329 21 12 20 Intentionally blank ...
Страница 50: ...12 Error codes 12 Service manual 487 0329 21 12 30 ...
Страница 66: ...29 Door and lint drawer 29 Service manual 487 0329 21 29 4 ...
Страница 80: ...40 Heating 40 Service manual 487 0329 21 40 4 I III II 6 7 Dismounting of the heating unit ...
Страница 99: ...487 0329 21 47 7 47 Gas system 47 Service manual ...