12.8
E 03 - Inlet air - Sensor has short-circuited
Error description
This error code indicates that the inlet air thermistor, connected to P18-1 and P18-2 on
the main circuit board, or the harness from the main circuit board circuit board to the
thermistor, has short circuited.
A defective detection circuit in the main circuit board can also cause this error.
The dryer stops operating.
Error analysis
2. Defective
NTC interface
on main circuit
board.
Measure the resistance of
the NTC sensor and
harness between P18-1
and P18-2 on the main
circuit board.
Is the resistance between
100 k
Ω
and 120 k
Ω
at
20°C (68°F)?
Replace NTC
sensor or harness.
(Section 27)
Go to step 2.
NO
YES
YES
Replace the main
circuit board.
(Section 21)
1. Defective
NTC sensor or
harness?
See section 27
Содержание T3300S
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...2 Technical data 2 Service manual 487 0329 21 2 4 ...
Страница 11: ...487 0329 21 3 1 3 Description of principal components 3 Service manual Contents Description 3 2 ...
Страница 20: ...11 Periodic maintenance 11 Service manual 487 0329 21 11 8 ...
Страница 40: ...12 Error codes 12 Service manual 487 0329 21 12 20 Intentionally blank ...
Страница 50: ...12 Error codes 12 Service manual 487 0329 21 12 30 ...
Страница 66: ...29 Door and lint drawer 29 Service manual 487 0329 21 29 4 ...
Страница 80: ...40 Heating 40 Service manual 487 0329 21 40 4 I III II 6 7 Dismounting of the heating unit ...
Страница 99: ...487 0329 21 47 7 47 Gas system 47 Service manual ...