27. Sensors and overheating thermostats
27
Service
manual
487 0329 21
27.2
Inlet air - Overheating thermostat
Function
The inlet overheating thermostat opens in the event of overheating, and shuts off the
dryer.
The thermostat opens automatically and has to be reset manually.
Resetting
Fig. 1 The overheating thermostat is located behind the grille near the fresh air inlet.
Fig. 2 In order to reset the thermostat, remove the cover plate A and reach one finger
into hole and depress the reset button on the back of the thermostat.
Error code
The following error code is related to this section.
E08
Refer to section 12 for more information.
A
A
1
2