Page 16
TESTER ERROR CODES
The following is a list of error codes the changer
tester will display via the digital display:
CCO - Changer Communication Error
This error occurs when the communication lines
between the changer and tester are not present
(changer not plugged in), broken or excessive noise
exists on the line.
NoCr - No Credit
This error will occur if a coin is accepted, but not
detected leaving the acceptor.
tUbE - Tube Sensor
This error exists when the changer's upper tube
sensor is blocked, while the lower tube sensor is not.
NOTE
: This error appears only during activity
pertaining to the defective tube. I.E. during
inventory or payout.
2Ar - Double Arrival
This error occurs if a second coin is detected within
1/2 second of the first coin accepted, or within 2
seconds if first coin was detected as a slug.
Section 5: Bench Check Procedure
ACPT - Acceptor Unplugged
This error occurs when the changer does not
communicate with the acceptor.
RoCh - ROM Check Sum
This error occurs when the changer's rom is
defective.
ROUT - Routing Error
This error occurs if a coin passes by the wrong outlet
sensor.
CoJA - Coin Jam Error
This error occurs when a coin is detected in the
validation coil for too long a time.
SLUG - Non-Valid Coin Type
This message occurs when the changer does not
recognize the coin.