Page 14
PROCEDURE
RESULT
FUNCTION VERIFIED
Turn tester power OFF. Remove
Upon power up, the
High Tube Sensor
acceptor from changer. Block
digital display and tube sensors
the coin change high tube sensors
upper and lower LED's sequence.
by completely filling tubes with
Coins are accepted and directed to
coins or by inserting a rolled up
cash box, digital display will read
tube of paper into the three coin
b.05, b.10, b.25 respectively and
tubes. Replace acceptor, turn
tube sensors upper and lower
tester power switch on and
LED's will illuminate
insert (1) nickel, (1) dime and (1) quarter
Insert (1) $ coin
$ coin is rejected
No $ accept switch
Insert a Canadian nickel, dime
Coin is rejected
U.S. coins only or
quarter coin switch
Set changer coin
Digital display will read rSt
control option switches as follows:
#1: (ON) Not Used.
#2: (ON) Lo $.25 Change tube
#3: (ON) $ coin accept
Actuate changer reset switch
Insert (1) $ coin
Coin is accepted and directed to
cash box, the digital display will
read b1.00
Block the middle $.25 change tube
Quarter is accepted and directed to Middle $.25 tube sensor
tube sensor without blocking the
the cash box. The digital display
high tube sensor by partially filling
will read b.25 and the upper and
$.25 change tube with coins
lower tube sensor LED's will
(approx. $5.00) or by inserting a
illuminate
rolled up tube of paper far enough
into $.25 change tube past the high
sensor but far enough into tube to
block the middle sensor. Insert (1)
quarter.
Section 5: Bench Check Procedure
BENCH CHECK PROCEDURE