ROUTINE  MAINTENANCE

Routine maintenance will improve performance and

extend the working life of the 9300 series changer

and reduce the need for more involved repairs.

Frequency of routine maintenance will depend on

environment and number of transactions.
The coin changer should be kept in its original

shipping carton when not in use.   This will keep the

changer clean and provide the best protection for the

unit.

REMOVING/REPLACING

INDIVIDUAL  MODULE

ASSEMBLIES

Modular assembly replacement provides the basis of

all 9300 series changer repair.  Instructions for

removing and replacing modules are provided below.

These modules should be removed in the following

sequence:

Acceptor

To remove the acceptor, raise the two acceptor

latches and pull the top of acceptor forward and

away from the changer housing.  Unplug acceptor

ribbon cable from main logic board.  Raise acceptor

and pull outward until the acceptor clears the housing

slots.

Coin Tube and Sensor Assembly

Remove the logic board cover by inserting a straight

tip screwdriver in the slot above the tube assembly.

Twist the screwdriver to release the ccover.
Unplug tube sensor ribbon cable from logic board.

Spread the lower part of the housing slightly and

pullout on tube assembly.  To separate the coin tube

assembly from the tube sensor board assembly, place

the assembly face down.  While freeing the four

locking tabs, pull up on tube sensor board.  Be

careful not to damage sensors on logic board.

Main Logic Board Assembly

Unplug payout solenoids, and main harness assembly

from logic board.  Lift logic board out of housing.

Section 4:  Maintenance

Payout Assembly

With payout solenoids disconnected from main logic

board, remove the four screws - two from each side-

at the bottom of the housing.  Separate payout

assembly from changer housing by releasing cash

box chute locking tab on back of changer housing

and pulling downward on payout assembly.

CLEANING

Your 9302-GX changer is made of a high-quality

industrial grade plastic which should only be cleaned

with a warm water and mild detergent solution.

CAUTION:

• Never  submerge  changer  in  water.

• Do  not  use  petroleum  solvents,  steel  wool,

scouring  pads,  or  a  metal  brush  for

cleaning.

• Do  not  spray  any  part  of  changer  with

any  type  of  lubricant.

Since all coins share a common coin ramp, heavy

usage or a dirty environment can result in dirt build

up.  To clean the coin ramp, lift the acceptor gate

upward and diagonally to the right.  Hold gate firmly

to prevent it from snapping back.  Wipe the exposed

coin ramp and inner surface with a damp cloth.  For

excessively dirty units, use a damp cloth with a mild

detergent.  

NOTE

:  Do not submerge in water.

For detailed cleaning of the acceptor, remove the

front cover by pulling out and down of the front

cover.  Now remove the back cover by pushing in on

two locking tabs on  the side of the acceptor.  To

remove the coin sorting rail, snap the coin sense coils

from the sorting rail and the cash box exit, being

careful not to break coil wires.  Free coil wires from

the clip on the sorting rail.  Now from the front of the

acceptor, in area exposed by removing the front

cover, locate the three locking tabs which secure the

sorting rail.  Using a small straight tip screwdriver,

free the three locking tabs and remove sorting rail.

See Figure 11.

Содержание CoinPro 3

Страница 1: ...Coinco 9302 GX SERIES ELECTRONIC CHANGER Operation and Service Manual ...

Страница 2: ...Operation 9 Escrow Return 9 Interface with Vendor Controller 9 Section 4 Maintenance Routine Maintenance 11 Removing ReplacingIndividualModuleAssemblies 11 Cleaning 11 Disassembling Payout Base 12 Clearing Coin Jams 12 Section 5 Bench Check Procedure Bench Check Procedure 13 Tester Error Codes 16 Section 6 Troubleshooting Introduction 17 TroubleshootingGuide 17 WiringDiagram 20 Section 7 Exploded ...

Страница 3: ...ers and dollar coins Pays out nickels dimes and quarters from self loading high capacity change tubes Change capacity of 40 55 Modular design for easy service Select high or low quarter tube level by simply flippingaswitch Heavy duty D C payout solenoids provide fast accurate payout State of the art electronic logic system is designed for reliability and performance Lightweight ruggedplasticconstr...

Страница 4: ...ative Humidity 20 to 98 Noncondensing Operating Attitude Vertical 3 degrees Physical Dimensions Height 14 81 inches high base to top of coin return lever Width 5 28 inches in width acceptor latch to acceptor latch Depth 2 86 inches gate closed Physical Weight in Shipping Carton 4 pounds Section 1 General Information 5 10 25 tube tube tube LO 25 LO 25 Option Option Switch Switch Set To Set To OFF O...

Страница 5: ...variety of coins to ensure proper operation NOTE SAVE THE COIN CHANGER CARTON Always store coin changer in its shipping carton when not in use This will keep the unit clean and protected OPTION SWITCH SETTING See Figure 2 0 1 Hinge acceptor down by releasing acceptor latches and pulling the top of the acceptor forward away from changer 2 Located in the upper portion of the changer behind the accep...

Страница 6: ...oin rail and enters the separator section of the acceptor The UPPER coin tube gate and the LOWER cash box gate are opened and closed by their respective solenoids These solenoids are energized and de energized by an electrical signal from the acceptor logic board based on the following criteria the validity of the coin the denomination of the coin the status full or empty of the appropriate coin t...

Страница 7: ...ge tube the cash box gate will open allowing the coin todrop into the vendor Section 3 Operation cash box via the changer cash box chute If the appropriate coin tube is not full full sensor not covered by coins the coin tube gate will open directing the coin down a ramp Along the wall of the ramp are windows for entry into the coin tube As the coin reaches a window of the appropriate size it falls...

Страница 8: ...are manually operated Coins are dispensed by D C solenoid operated slides located at the bottom of each of the three coin tubes The payout solenoids are controlled by signals generated by the vendor controller or the three inventory switches When a solenoid energizes the upward motion of its plunger compresses a spring and draws the solenoid lever which in turn pushes a payout slide forward This l...

Страница 9: ...he middle 25 tube sensor is blocked by coins The low tube sensors in each coin tube continually report the blocked not blocked coin level status to the vendor controller This information is used to determine if change is available for payout CORRECT CHANGE OPERATION The coin changer continually reports the status of the low tube sensors to the vendor s controller The logic control for correct chan...

Страница 10: ...Page 10 Section 3 Operation Figure 9 Figure 10 9302 GX Controller Vendor Interface ...

Страница 11: ...from logic board Lift logic board out of housing Section 4 Maintenance Payout Assembly With payout solenoids disconnected from main logic board remove the four screws two from each side at the bottom of the housing Separate payout assembly from changer housing by releasing cash box chute locking tab on back of changer housing and pulling downward on payout assembly CLEANING Your 9302 GX changer is...

Страница 12: ...th bottom screws Reinstall payout module into changer securing with side screws CLEARING COIN JAMS Should a coin jam occur in the cash box chute area use the following steps to help dislodge coins 1 Remove changer from vendor 2 Keeping changer in an upright position insert a narrow screwdriver into cash box chute or reject chute from bottom of changer to relieve jam Access holes are also provided ...

Страница 13: ...t the changer Enable Disable Coins are accepted and Coin accept switch to the Enable up directed to the respective changer accepted function position and insert 1 nickel coin tube digital display will read 1 dime and 1 quarter t 05 when nickel is deposited t 10 when dimes is deposited t 25 when quarter is deposited Actuate Changer Reset Switch Digital display will read rSt Reset NOTE If reset swit...

Страница 14: ... nickel dime Coin is rejected U S coins only or quarter coin switch Set changer coin Digital display will read rSt control option switches as follows 1 ON Not Used 2 ON Lo 25 Change tube 3 ON coin accept Actuate changer reset switch Insert 1 coin Coin is accepted and directed to cash box the digital display will read b1 00 Block the middle 25 change tube Quarter is accepted and directed to Middle ...

Страница 15: ...rs are covered the lower tube sensor LED will illuminate if both upper and lower tube sensors are blocked both upper and lower tube sensors LED s will illuminate Actuate the 5 10 25 inventory The digital display will read Pay out control switches n d P respectively and number of coins payed out I E n 03 for 3 nickels p 03 for 3 quarters and d 03 for 3 dimes Section 5 Bench Check Procedure BENCH CH...

Страница 16: ...r appears only during activity pertaining to the defective tube I E during inventory or payout 2Ar Double Arrival This error occurs if a second coin is detected within 1 2 second of the first coin accepted or within 2 seconds if first coin was detected as a slug Section 5 Bench Check Procedure ACPT Acceptor Unplugged This error occurs when the changer does not communicate with the acceptor RoCh RO...

Страница 17: ...rrectly Connector pins are not bent or broken All wires are properly secured Inventory tubes are filled to their correct levels NOTE The following Troubleshooting Guide is based on the fact that the tester or vendor with which the defective changer is being tested functions properly when used with a known good changer This guide is not intended to cover all failures but to cover the most common fa...

Страница 18: ...atic credit Replacechanger main logic board If still no erratic credit Replacechanger mainpowerharness Accepted coins Tubesensorboard Checkthesensorboardfor Replacetube always go to oracceptor looseorbrokencomponents sensorboard cash box Makesuretubesensorboard isproperlysecuredtothetube assembly Checkcablefrom sensorboardfordamageor improperconnection If coin still goes to cash box Replaceaccepto...

Страница 19: ...ut Coinreturnlever Makesurechangerismounted Repositionchanger doesnotescrow correctlyandacceptorgate and or vendor coin openswhenvendorcoinreturn returnlever leverisoperated Acceptor Replace acceptor with good Replacedefective acceptorandtest acceptor If changer functions properly If still no escrow Replacechanger main logic board No payout Payoutsolenoid Makesuresolenoidwiresare Plugsolenoidwires...

Страница 20: ...Page 20 Section 6 Troubleshooting 9302 GX Wiring Diagram ...

Страница 21: ...007 Harness 1 2 407400 3 Logic Board 1 Gray Connector 407400 2 Logic Board 1 Black Connector 3 922331 7 Changer Housing 1 4 407978 4 Payout Assembly 1 5 406728 12 Inventory Tube Assembly 1 6 407755 2 Acceptor 1 Gray Connector 407755 1 Acceptor 1 Black Connector 7 406789 Logic Bd Cover Label Assy 1 ...

Страница 22: ...ge 22 Section 7 Exploded Views Changer Housing Item No Part No Description Qty 1 922331 7 Housing only 1 2 902011 1 Acceptor Latch Right 1 3 902010 1 Acceptor Latch Left 1 4 909729 Label Indentification 1 ...

Страница 23: ...07 4 Solenoid Assembly 24VDC 3 2 909113 Pivot Shaft 1 3 909141 Upper Payout Base 1 4 909630 Screw 6 32 x 3 16 6 5 909105 10 Payout Slide 1 6 909104 5 Payout Slide 1 7 909103 25 Payout Slide 1 8 909102 1 Lower Payout Base 1 9 345P4R7 Screw 4 x 7 16 8 10 909106 Solenoid Lever 3 11 909135 Coin Return Liner 1 ...

Страница 24: ... 1 Assembly Inventory Tube 406728 12 Assembly Item Part No No Description Quantity 1 922332 3 Logic Bd Cover 1 2 910889 2 Label Switch 1 Options Item Part No No Description Quantity 1 909115 4 Inventory Tube 1 Label 2 406728 12 Inventory Tube 1 Board Assembly ...

Страница 25: ...95 2 Front Cover Assy 1 5 906606 1 Operating Lever 1 6 906624 Screw Gate Lever 1 Pivot 7 751S21X Retaining Ring 1 Item Part No No Description Quantity 8 906618 Spring Oper Lev 1 9 400 8 Nut 8 32 Lock 1 10 406611 Mainplate Coil Assy 1 11 345 4R5 Screw 4x5 16 PH 2 12 906616 Coin Rail 1 13 923995 Acceptor Label 1 14 924241 CoinPro Decal 1 15 921625 1 4 LED Labels 4 16 923984 Gate Core Foam 1 ...

Страница 26: ... 406857 3 Solenoid 2 Assembly 16 922609 Mainplate Foam 1 17 406613 1 Coil Assy Sensing 1 18 908845 1 Plug Spring 2 Retention 19 921624 PVC Foam 1 Item Part No No Description Quantity 1 406611 Mainplate Coils 1 2 406167 Plunger Yoke 2 Assembly 3 906619 2 Spring 1 Copper plated 4 406619 1 Spring 1 Nickel plated 5 909096 1 Back Cover 1 6 407506 23 Board Assembly 1 9300 Acceptor 7 406612 Rear Chute Co...

Страница 27: ...Page 27 Notes ...

Страница 28: ...Coinco Publication No 925054 Rev 1 8 00 Printed in the U S A COIN ACCEPTORS INC 300 Hunter Avenue St Louis MO 63124 2013 314 725 0100 or 800 325 COIN ...

Отзывы: