Page 19
Section 6: Troubleshooting
TROUBLE
POSSIBLE CAUSE
PROCEDURE
REMEDY
Accepted quarters go
Quarter coin tube
Check to see that quarter coin
Fill quater coin
to quarter coin tube when has less than 22
tube has a minimum of 22
tube with 22
Lo-$.25 switch is ON
quarters
quarters
quaters to cover
Lo-$.25 sensor
Tube sensor board
Replace tube sensor board
Replace tube
with good tube sensor board
sensor board
and test
If changer functions properly . . .
If coins still go to quarter tube . . .
Replace changer
main logic board
Credits coins but
Coin return lever
Make sure changer is mounted
Reposition changer
does not escrow
correctly and acceptor gate
and/or vendor coin
opens when vendor coin return
return lever
lever is operated
Acceptor
Replace acceptor with good
Replace defective
acceptor and test
acceptor
If changer functions properly . . .
If still no escrow . . .
Replace changer
main logic board
No payout
Payout solenoid
Make sure solenoid wires are
Plug solenoid wires
properly connected to changer
into logic board
main logic board
If still no payout, replace solenoid
Replace defective
with good solenoid and test
payout solenoid
If changer operates properly . ..
If still no payout . . .
Rplace changer
main logic board
If still no payout . . .
Replace changer
main power harness
9302-GX TROUBLESHOOTING GUIDE