CREDIT  AND  ACCUMULATION

See  Figure  7

There are two sensors, one in the separation section

of the acceptor and one in the cash box path of the

acceptor.  As coins pass either one of these sensors,

the changer sends credit information to the vendor

electronic controller where the coin credit is

accumulated.

MAIN LOGIC BOARD

The main logic board is responsible for all logic

functions of the changer.  It receives information

from other changer modules as well as the vending

machine, and based on this information, controls the

operation of the changer.
The main logic board also contains the changer

power supply.  It receives the incoming AC voltage

from the vendor and does the following:  First, it is

rectified to a DC voltage for the payout solenoids.

Second, it is routed to the transformer’s primary

where it is reduced to 12 VAC.  This 12 VAC is

routed back to the logic board where it is rectified

and filtered to the operating DC voltage.

COIN TUBE SENSING

See  figure  8

The low tube sensors in each coin tube continually

report the (blocked/not blocked) coin level to the

microprocessor.  This information is used to

determine the availability of change for change

payback, escrow and exact change condition.
The full tube sensors in each coin tube continually

report the (full/not full) status to the coin changer’s

microprocessor.  The information is then used to

determine the placement of the next accepted coin.

This information controls the action of the acceptor

coin tube and cash box gates.
EXAMPLE:  If the quarter coin tube is full (full

sensors blocked by coins) the acceptor coin tube

gate will remain closed and the cash box gate will

open each time a quarter is accepted, routing all

quarters to the vendor cash box via the changer coin

chute.  After one or more quarters is paid out as

change, leaving the full sensor exposed (quarter tube

not full), the acceptor coin tube gate will open each

time a quarter is accepted, routing quarters to the

changer coin tube until it is full again.

Section 3:  Operation

Figure  7

Figure  8

Содержание 9300-S Series

Страница 1: ...Coinco 9300 S SERIES ELECTRONIC CHANGER OperationandServiceManual...

Страница 2: ...n 10 Coin Payout 10 DollarCreditEscrowOption 10 Escrow 10 EscrowUntilVend ChangerVendorInterface 11 EscrowUntilSelect ChangerVendorInterface 12 Section 4 Maintenance Routine Maintenance 13 Removing Re...

Страница 3: ...g coin tubes and accept nickels dimes quarters and dollar coins The 9341 S directly interfaces with the standard 6 pin bill validator interface cable and non standard bill acceptors 12 pin connector T...

Страница 4: ...ation Section 1 General Information SPECIFICATIONS Power Requirements 9341 S 120 VAC 60HZ 9360 S 95 to 130 VAC 60HZ 350 m Amp Max Operating 1 Amp Max During Payout 9342 SC 24 VAC 60 HZ 20 to 32 VAC 60...

Страница 5: ...e unit clean and protected Section 2 Installation SWITCH PRICE OPTION 1 05 2 10 3 20 4 40 5 80 6 1 60 7 3 20 8 6 40 9 NOTUSED 10 coin acceptance 11 LO 25 12 escrow until select VEND PRICE AND OPTION S...

Страница 6: ...Page 6 Section 2 Installation Figure 2...

Страница 7: ...in rail and enters the separator section of the acceptor The UPPER coin tube gate and the LOWER cash box gate are opened and closed by their respective solenoids These solenoids are energized and de e...

Страница 8: ...e tube the cash box gate will open allowing the coin todrop into the vendor Section 3 Operation cash box via the changer cash box chute If the appropriate coin tube is not full full sensor not covered...

Страница 9: ...d to the operating DC voltage COIN TUBE SENSING See figure 8 The low tube sensors in each coin tube continually report the blocked not blocked coin level to the microprocessor This information is used...

Страница 10: ...ger compresses a spring and draws the soenoid lever which in turn pushes a payout slide forward This loads the coin for payout When the solenoid de energizes the spring force returns the plunger to it...

Страница 11: ...nables the selection switches for vending The changer s vend relay s N C contact connects the AC hot line to the vendor s credit relay s N O contact When a selection switch is activated the vendor s v...

Страница 12: ...of the hot AC signal to Jones plug line six the changer will stand by for the next transaction If an escrow is detected while waiting for the hot AC signal to Jones plug line six to break then the hot...

Страница 13: ...logic board Lift logic board out of housing Section 4 Maintenance Payout Assembly With payout solenoids disconnected from main logic board remove the four screws two from each side at the bottom of t...

Страница 14: ...plate securing with bottom screws The transformer s black wires must be to the right away from the solenoids Reinstall payout module into changer securing with side screws CLEARING COIN JAMS Should a...

Страница 15: ...anger is being tested functions properly when used with a known good changer This guide is not intended to cover all failures but to cover the most common failures Section 5 Troubleshooting TROUBLE PO...

Страница 16: ...money but Open circuit CheckcontinuitybetweenJones Ifopen replacemainharness will not vend plug pin 3 P3 pin 6 see fig 14 16 CheckcontinuitybetweenJones Ifopen replacemainharness plug pin 7 P3 pin 5 L...

Страница 17: ...still goes to cash box Replaceacceptor If coin still goes to cash box Replace main logic board Coin always goes to Coin tube gate in open Removeacceptorbackcover Repleaceacceptor coin tubes position c...

Страница 18: ...Page 18 9341 S Wiring Diagram fig 14 Section 5 Troubleshooting...

Страница 19: ...Page 19 Section 5 Troubleshooting 9342 S Wiring Diagram fig 15...

Страница 20: ...Page 20 Section 5 Troubleshooting 9360 S Wiring Diagram fig 16...

Страница 21: ...Page 21 9300 S Series Changers Section 6 Accessories...

Страница 22: ...Board 9341 S 9360 S BLACK acceptor connector 407336 4 Logic Board 9342 SC GRAY acceptor connector 3 922331 ChangerHousing 1 4 407978 1 PayoutandHousingAssembly 1 includes 3 117 volt 9341 S 9360 S 4079...

Страница 23: ...Part No Description Qty Note 1 922331 Housing only 1 2 902011 1 Acceptor Latch Right 1 3 902010 1 Acceptor Latch Left 1 4 909729 Label Indentification 1 5 902224 24 VOLTS ONLY decal 2 9342 SC only 6...

Страница 24: ...ndcut blk 6 5 406606 3 Transformerassy 110VAC fused 1 9360 S 9341 S 6 909105 10 Payoutslide 1 7 909104 5 Payoutslide 1 8 909103 25 Payoutslide 1 9 922496 Lowerpayoutbase 1 10 345P4R7 Screw 4 x 7 16 PH...

Страница 25: ...r Assembly Inventory Tube Assembly Item Part No No Description Quantity 1 922332 1 Logic Board Cover 1 2 923058 Label 1 Switch Options Item Part No No Description Quantity 1 909115 4 Inventory Tube 1...

Страница 26: ...Cover 1 4 909095 2 Front Cover 1 5 906606 1 Operating Lever 1 6 906624 Screw Gate Lever 1 Pivot 7 751S21X Retaining Ring 1 Item Part No No Description Quantity 8 906618 Spring Oper Lev 1 9 400 8 Nut 8...

Страница 27: ...96 1 Back cover 1 6 407506 23 Boardassy CoinProacceptor 1 7 406612 Rear chute and coil assy 1 8 909095 2 Frontcover 1 9 906596 1 Covergate 1 10 906622 2 Pin diverterpivot 2 11 345S4R7 Screw 4 x 7 16 P...

Страница 28: ...Coinco Publication No 925197 Rev 1 2 01 Printed in the U S A COIN ACCEPTORS INC 300 Hunter Avenue St Louis MO 63124 2013 314 725 0100 or 800 325 COIN...

Отзывы: