6X-1105D
Grounding
• To provide protection against electrical surges induced by lightning, static charges, or any other
cause, the camera and cabling system must be properly grounded to earth. For installation on a
building, the camera must be bonded (that is, provided with a low impedance connection) to the
building’s structural earth ground system. For installation on a metal pole with a proper ground
system at the base, the camera must be bonded to the pole. For installation on a non-grounded or
insulated support, the camera must be grounded with an adequate ground strap or wire between
the camera and a nearby ground system, or to a ground system installed at the base of the sup
-
port. Failure to adequately ground the camera may lead to failure of the camera. This applies to
low voltage (i.e. PoE cameras) as well as to 115 Vac cameras.
Failures due to surges are not
covered by the warranty, as they are not due to defects in material or workmanship, and it is
the installer’s responsibility to meet these grounding requirements
.
• All system cables must be shielded, and the shield(s) must be bonded to earth ground.
•
8800
HD
Standalone Camera System
: The grounding screw on the camera’s rear panel (see p7)
must be connected to earth ground using minimum 16 AWG wire and bonded to earth ground as
close to the camera as possible.
•
8800
HD
Camera
Positioner System
: Except for the cable shield(s), the camera positioner system
does not require grounding. Power return is connected to chassis ground.