![CohuHD Costar 8800HD Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/cohuhd-costar/8800hd/8800hd_installation-manual_2634971024.webp)
24
6X-1105D
3.2.5 Parapet Mount Installation. CohuHD p/n 8185-6
Use the mount adapter, wall mount, support strut, and parapet mount for installation to a parapet. See
Figure 12 for a typical installation diagram and Figures 15, 16, 17, and 20 for mount dimensions.
Bolt, Hex Head 1/4-20x3/4”L, SS (4)
Washer, Spring Lock 1/4”, SS (4)
Washer, Flat 1/4”, SS (4)
(supplied)
Bolt, 1/4-20 (4)
(supplied)
Wall Mount
Bolt, Hex Head, 5/16-18x1½”L, SS (4)
Washer, Flat 5/16”, SS (8)
Washer, Spring Lock 5/16”, SS (4)
Nut, Hex, 5/16”, SS (4)
(supplied)
Support Strut
Mount Adapter
Bolt, Hex Head, 1/4-18x1½”L, SS (3)
Washer, Flat 1/4”, SS (6)
Washer, Spring Lock 1/4”, SS (3)
Nut, Hex, 1/4”, SS (3)
(supplied)
Wall Swivel
Clamp Swivel
Positioner Adapter Plate
The Wall Mount Flange connects
to the Parapet Flange (see below)
Figure 12. Installation to a Parapet
The parapet mount:
•
Installs on the inside of a parapet that is at least 18 inches (457.2 mm) high.
• Is rotatable 360° so the camera positioner system can be installed from the roof.
Flange
Upper Mounting
Bracket
U-Bolts
Lower Mounting
Bracket
Fasteners
Minimum 1/4” DIA
(not supplied)
Tube assembly
is rotatable 360
°