background image

Vision System Specifications

Specification

3D-L4050

3D-L4100

3D-L4300

Operating Temperature

0ºC to 35ºC (32ºF to 95ºF) without heat sink
35ºC to 45ºC (95ºF to 113ºF) with heat sink

Storage Temperature

-20ºC to 70ºC (-4ºF to 158ºF)

Humidity

20% to 80%, non-condensing (Operating and Storage)

Protection

IP65 with all cables properly attached and M/S TRIG connectors capped.

Shock

15 G’s, 6 milliseconds half sinusoidal

Vibration

10 to 57, double amplitude 1.5 mm X,Y,Z, 3 hours in each direction

Cleaning and maintenance

This chapter gives an overview about the cleaning and maintenance of the vision
system.

Clean the Housing

To clean the outside of the vision system housing, use a small amount of mild
detergent cleaner or isopropyl alcohol on a cleaning cloth. Do not pour the cleaner
on the vision system housing.

CAUTION

:

Do not attempt to clean any In-Sight product with harsh or

corrosive solvents, including lye, methyl ethyl ketone (MEK) or gasoline.

5

Содержание In-Sight 3D-L4000 Series

Страница 1: ...In Sight 3D L4000 Series Vision System Manual 2021March08 Revision 1 0 0 90...

Страница 2: ...In Sight 3D L4000 Series 2...

Страница 3: ...the connectors on the vision system Do not force the connections or damage may occur Mount the Vision System Top Housing 1 Align the holes on the mounting surface with the mounting holes on the visio...

Страница 4: ...grounded Ethernet connector A digital voltmeter should be used to validate the grounding If the far end device is not grounded a ground wire should be added in compliance with local electrical codes...

Страница 5: ...G s 6 milliseconds half sinusoidal Vibration 10 to 57 double amplitude 1 5 mm X Y Z 3 hours in each direction Cleaning and maintenance This chapter gives an overview about the cleaning and maintenanc...

Страница 6: ...for cleaning the laser and vision system windows l Unplug the unit so the laser cannot be enabled l Use lint free tissue or an optical grade cotton swab Q tip l Use reagent grade isopropyl alcohol l...

Страница 7: ...standards for laser products except for conformance with IEC 60825 1 Ed 3 as described in Laser Notice No 56 dated May 8 2019 WARNING Use of controls or adjustments or performance of procedures other...

Страница 8: ...ay have an impact on laser safety to your supervisor or Laser Safety Officer l There is no scheduled maintenance necessary to keep the product in compliance l Under no circumstances should you operate...

Страница 9: ...ilure to follow these instructions may cause serious injury WARNING Avoid exposure laser radiation is emitted from this aperture Regulations and Conformity Note For the most current CE declaration and...

Страница 10: ...rference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructio...

Страница 11: ...epared in accordance with the provisions of SJ T 11364 SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement o...

Страница 12: ...the pressure on the natural resources we encourage you to use the appropriate take back systems for product disposal Those systems will reuse or recycle most of the materials of the product you are di...

Страница 13: ...ble national and local wiring standards and rules must be followed l This product is intended for industrial use in automated manufacturing or similar applications l The safety of any system incorpora...

Страница 14: ...nector Cable shielding can be degraded or cables can be damaged or wear out faster if a service loop or bend radius is tighter than 10X the cable diameter l The vision system s M S connectors are not...

Страница 15: ......

Страница 16: ...Copyright 2020 Cognex Corporation All Rights Reserved...

Отзывы: