Precautions
To reduce the risk of injury or equipment damage, observe the following precautions
when you install the Cognex product:
l
The vision system requires a UL or NRTL listed power supply with a 24VDC
output that meets the following rating requirements:
l
At least 1A continuous current.
l
A maximum short circuit current of less than 4A.
l
A maximum power of less than 50VA and marked as a Limited
Power Source (LPS) or National Electrical Code (NEC) Class 2.
Any other voltage creates a risk of fire or shock and can damage the
components. Applicable national and local wiring standards and rules must
be followed.
l
This product is intended for industrial use in automated manufacturing or
similar applications.
l
The safety of any system incorporating this product is the responsibility of
the assembler of the system.
l
Do not install Cognex products where they are exposed to environmental
hazards such as excessive heat, dust, moisture, humidity, impact, vibration,
corrosive substances, flammable substances, or static electricity.
l
Route cables and wires away from high-current wiring or high-voltage
power sources to reduce the risk of damage or malfunction from the
following causes: over-voltage, line noise, electrostatic discharge (ESD),
power surges, or other irregularities in the power supply.
13