l
Recommended: Attach the sensor to the DS1000 series high-accuracy mounting plate. See the topic
for more information.
l
Use the mounting bosses on the top of the device. See the topic
for more information.
l
Use the mounting through-body holes on the side of the device. See the section
for more information.
High-Accuracy Mounting
The mounting plate (part number DS-MPHA-00) accessory offers the following advantages when anchoring your sensor
to your production environment:
l
The laser plane will always be parallel to the mounting plate.
l
Removing and replacing a sensor requires fewer steps and allows you to mount a new sensor in exactly the
same position as the previous unit.
Be aware of the following mounting features for use with the mounting plate:
Feature
Description
Usage
1
Plane Pins (3 total)
Ensures that the laser plane is parallel to the
mounting plate.
2
Location Pin
Constrains the rotation of the sensor around the
Master Pin.
3
M6 screw thread
4
Master Pin
22