The
miniCYC MB
utilises the Philips MSD/2 250W with GY 9,5 base lamps.
These lamps are available via your
Coemar
distributor or service centre.
The fixture’s internal temperature can reach 250° C after 5 minutes, with a maximum peak of 350° C; ensure that the lamp is cold prior
to attempting removal. The fixture should be allowed to stand and cool for 10 minutes prior to its removal.
The lamps are part of the mercury vapour family of discharge lamps and must be handled with great care. The lamp operates at high
pressure, and the slight risk of explosion of the lamp exists if operated over its recommended life. We recommend, therefore, that the
lamp be replaced within the manufacturer’s specified lamp life.
9.1. Lamp installation
1.
Identify the two lampholder assembly, left and right “
A
“. Use a suitable
tool to loosen the screws “
B
“ which affix the lampholder assembly at
the rear of the projector
2.
Remove the lampholder assembly “
C
”.
C
A
B
ATTENTION!!
Disconnet the unit from mains power prior to attempting lamp installation or replacement
Make sure the projector is sufficiently cooled.
Lamp
Philips MSD/2 250W
Coemar
code
105214/1
Power
250W
Luminous flux
18.000 lm
Colour temperature
8500° K
Base
GY 9,5
Approximate lamp life
2000 huors