Locate the ballast inside the base.
Cables
32
and
42
determine the operating voltage and frequency. Move them to the required value: 208V/60Hz, 230V/50Hz or
240V/50Hz on the ballast. Refer to the stickers on the ballast to ensure correct selection is made.
Cables number 33 and 43 must not have its position altered under any circumstances
!
When you have made changes, note these on the outside of the
miniCYC MB
.
Replace and fasten all the housings as per their original positions.
5.3. Mains connection
Mains cable characteristics
The mains cable provided is thermally resistant, complying to the most recent international standards. It meets or exceeds VDE and IEC
norms, IEC 331,IEC 332 3C,CEI 20 35.
NB: In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5 ø exter-
nal 10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°,
Coemar
cod. CV5309).
Connecting to mains power
For connection purposes, ensure your plug is of a suitable rating to sustain the maximum current:
•208/230/240V
3.5 amps constant current in normal operation
Locate the mains cable which exits the base of the unit and connect as shown below:
ATTENTION!!
• The use of a thermal magnetic circuit breaker is recommended for each projector.
Strict adherance to all regulatory norms is higly recommended.
• miniCYC MB should never be supplied mains power via a Dimmer; this is potentially dangerous.
• Prior to powering up the projector, ensure that the model in your possession correctly mathces the mains supply avai-
lable to you.
• A good earth connection is essential for the correct operation of the miniCYC MB. Never connect the projector to main
power if the green/yellow earth cable is not correctly connected
• All cable and plug connections should be carried out by fully qualified and licenced personnel only.
ground
neutral
live
brown
blue
yellow/green
main
Ph
208V/60Hz
230V/50Hz
240V/50Hz
Ph
208V/60Hz
230V/50Hz
240V/50Hz
43
42
32
33
11
English