background image

13

English

9

color mode

step

full color

0 - 63

0% - 25%

half color

64 - 127

25% - 50%

proportional proportional color

128 - 191

50% - 75%

step

rainbow

192 - 255

75% - 100%

10

cyan

proportional proportional control of the percentage of cyan color in the light beam 

from 0 to 100% 

0 - 255

0% - 100%

11

magenta

proportional proportional control of the percentage of magenta color in the light 

beam from 0 to 100% 

0 - 255

0% - 100%

12

yellow

proportional proportional control of the percentage of yellow color in the light 

beam from 0 to 100% 

0 - 255

0% - 100%

13

speed CMY

step

no effect

0 - 7

0% - 3%

proportional varable speed from fast to slow

8 - 255

3% - 100%

14

macro CMY

step

no effect

0 - 9

0% - 4%

macro 1

10 - 14

4% - 5%

macro 2

15 - 19

6% - 7%

macro 3

20 - 24

8% - 9%

macro 4

25 - 29

10% - 11%

macro 5

30 - 34

12% - 13%

macro 6

35 - 39

14% - 15%

macro 7

40 - 44

16% - 17%

macro 8

45 - 49

18% - 19%

macro 9

50 - 54

20% - 21%

macro 10

55 - 59

22% - 23%

macro 11

60 - 64

24% - 25%

macro 12

65 - 69

25% - 27%

macro 13

70 - 74

27% - 29%

macro 14

75 - 79

29% - 31%

macro 15

80 - 84

31% - 33%

macro 16

85 - 89

33% - 35%

macro 17

90 - 94

35% - 37%

macro 18

95 - 99

37% - 39%

macro 19

100 - 104

39% - 41%

macro 20

105 - 109

41% - 43%

macro 21

110 - 114

43% - 45%

macro raimbow wait - 1

115 - 121

45% - 47%

macro raimbow wait  - 2

122 - 128

48% - 50%

macro raimbow wait  - 3

129 - 135

51% - 53%

macro raimbow wait  - 4

136 - 142

53% - 56%

macro raimbow wait  - 5

143 - 149

56% - 58%

macro raimbow wait  - 6

150 - 156

59% - 61%

macro raimbow wait  - 7

157 - 163

62% - 64%

macro raimbow wait  - 8

164 - 170

64% - 67%

macro raimbow wait  - 9

171 - 177

67% - 69%

macro raimbow wait - 10

178 - 185

70% - 73%

full colors raimbow wait - 1

186 - 192

73% - 75%

full colors raimbow wait - 2

193 - 199

76% - 78%

full colors raimbow wait - 3

200 - 206

78% - 81%

full colors raimbow wait - 4

207 - 213

81% - 84%

full colors raimbow wait - 5

214 - 220

84% - 86%

full colors raimbow wait - 6

221 - 227

87% - 89%

full colors raimbow wait - 7

228 - 234

89% - 92%

full colors raimbow wait - 8

235 - 241

92% - 95%

full colors raimbow wait - 9

242 - 248

95% - 97%

full colors raimbow wait - 10

249 - 255

98% - 100%

Содержание Infinity Spot L

Страница 1: ...Instruction manual Version 1 0 Infinity Spot L...

Страница 2: ......

Страница 3: ...u purchased your Infinity Spot L this information will assist us in providing spare parts repairs or in answering any technical enquiries with the utmost speed and accuracy WARNING the security of the...

Страница 4: ......

Страница 5: ...Special mode and electronic motor alignment 18 10 Lamp installation and alignment 19 10 1 Lamp installation 19 10 2 Aligning the lamp in the optical path 20 11 Operating on internal groups 21 11 1 Ho...

Страница 6: ...vel of technology of Infinity Spot L requires the use of specialised personnel for all service applications refer all work to your authorised Coemar service centre 4 A good earth connection is essenti...

Страница 7: ...nd the model of the projector are required for any advice or service from your authorised service centre 2 3 EC Norms The projector meets all fundamental applicable EC requirements Protection rating a...

Страница 8: ...ns on a reticular structure Coemar provides a set of Cam lock support brackets which are included in the packaging The Cam lock bracket is one fourth turn supports Before using it for supporting the p...

Страница 9: ...inity Spot L projector moves du ring its operation Make sure that the supporting structure is not subject to torsion Do not install the projector in locations readily accessible by unauthorised or unt...

Страница 10: ...connect as shown below Mains cable characteristics The mains cable provided is thermally resistant complying to the most recent international standards Note in case of cable replacement similar cable...

Страница 11: ...controlled by a DMX 512 signal for further information see section 7 2 DMX functions When powered up initially each projector will show A001 which indicates DMX address 001 a projector thus addres sed...

Страница 12: ...h sec 115 119 45 47 strobe frequency 9 7 0 flash sec 120 124 47 49 strobe frequency 10 8 0 flash sec 125 129 49 51 strobe frequency 11 9 0 flash sec 130 134 51 53 strobe frequency 12 10 0 flash sec 13...

Страница 13: ...ro 10 55 59 22 23 macro 11 60 64 24 25 macro 12 65 69 25 27 macro 13 70 74 27 29 macro 14 75 79 29 31 macro 15 80 84 31 33 macro 16 85 89 33 35 macro 17 90 94 35 37 macro 18 95 99 37 39 macro 19 100 1...

Страница 14: ...L speed 1 slow 10 22 4 9 gobo shake R L speed 2 23 35 9 14 gobo shake R L speed 3 36 48 14 19 gobo shake R L speed 4 49 61 19 24 gobo shake R L speed 5 62 74 24 29 gobo shake R L speed 6 75 87 29 34...

Страница 15: ...iris pulsed effect at different speed from min to max 10 63 4 25 iris pulse with flash closing from min to max 64 117 25 46 iris pulse with flash closing from max to min 118 171 46 67 step spare 172...

Страница 16: ...lue DISPLAY SETUP NOT USED MAIN FUNCTIONS MEASURES DISPLAY SETUP allows the management of brightness positive or negative graphic backlight shutdown time buttons shutdown time 180 display reverse MAIN...

Страница 17: ...ettable unit life fixture s life USAGE HOURS It shows the actual installed software version sw LCD master software installed on to LCD master board sw MOTOR slave software installed on to MOTOR slave...

Страница 18: ...emar at the factory during the testing in order to obtain particular effects or in the case of internal components being replaced motors electronic boards sensors etc it may be necessary to change thi...

Страница 19: ...dled with care always adhere to the instructions provided in the lamp packaging Never touch the glass directly use the polythene wrapping provided in the lamp packaging DO NOT USE UNDUE FORCE ON THE G...

Страница 20: ...ed out by using the 3 screws A B and C showed in the picture below The lamp should be on black out and dimmer fully open and no colours selected If the lamp is not correctly aligned a hot spot to the...

Страница 21: ...ws A from the upper housing and remove this In order to identify the upper housing to be removed position the unit so that the printing on the lamp holder group can be read the printing must not upsid...

Страница 22: ...case gobo s thickness must never be below 0 5 mm Type of gobo Working area mm Thickness mm Overall diameter mm Metal gobos Up to 21 0 5 Up to 21 Glass gobos undefined Up to 27 from 1 to 4 Up to 26 8...

Страница 23: ...3 Remove the old gobo 4 Insert the new gobo respecting the black side Avoid to touch the uncoated side 5 On the gear there is an etched reference point use it to orient the gobo and fix on to the proj...

Страница 24: ...gobos on gobos 2 wheel 1 Facing the front side of the wheel gently hold the gobo you want to replace with thumb and finger then lift it up pushing it with your finger then remove it 2 Insert the new g...

Страница 25: ...sert the new filter facing the coated side downwards making it slip under the spring until it locks respect the coated side of the filter bottom side NB The wheel only accepts glass filters or gobos w...

Страница 26: ...groups in place just follow backwards the procedure explained at the beginning of this chapter half insert the gobo assembly and incline it toward the front of the fixture Insert the colour changer a...

Страница 27: ...ce Lamp Check the lamp and replace it if there is any observable damage or deformation or if or if the time limit is close check the resettable counter Mechanical parts Periodically check the movement...

Страница 28: ...e PAN movement motor check the motor and the relevant cabling ERR Encoder TILT TILT encoder not found Check the sensor of the encoder wheel placed on the fixture s yoke to detect the position of the T...

Страница 29: ...l The projector is too hot Let the fixture cool down Check that the air vents above the cooling fans are not obstructed and that the fans are working correctly Ensure that the ambient emperature is be...

Страница 30: ...Lighting s r l via Carpenedolo 90 46043 Castiglione delle Stiviere Mantova Italy ph 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar reserves the right to effect modifications without notifi...