background image

https://codelocks.zohodesk.eu/portal/en/kb/articles/cl5500-installation-instructions

Cables are provided for the REM 1 and REM 2 terminals on the circuit board.

 

REM 1 is for connection to a reception desk push button or a door intercom system. Pressing the button will
cause the keypad to flash blue on the lock and release the lock for the pre-set time.

REM 2 is for connection to the building alarm system to release a door in an emergency. This allows rooms,
wards, offices to be easily checked to ensure that no person is trapped or overlooked during an emergency
evacuation. When activated REM 2 will maintain the unlocked condition for 30 minutes, the keypad will flash
red and BEEP during this time.

OTHER OPTIONS

Alternative functionality can be configured for the REM connections including support for connection to dry
contact door sensors. For further information, please refer to the online documentation at

www.codelockssupport.com.

 

REM 1 and REM 2 should only ever be used with un-powered switches or sensors. Connecting powered devices
to these connectors will damage your lock.

Fire Kit
A Fire Kit pack is available for the CL5510 locks. When fitted, they can be installed on 30 or 60 minute fire
doors.
Tested in accordance with BS3N1634-1:2008.
For more information about the Fire Kit packs please contact Codelocks 

www.codelocks.com

 

Functions

CL5510 Latch Function
Outside handle turns freely without operating the latchbolt. When the code is entered the keypad will flash blue
and the handle will retract the latchbolt. The latch automatically locks the door when closed. The key will open

Содержание CL5500 SERIES

Страница 1: ...tallation instructions Codelocks Support CL5500 Installation Instructions Box Contents Check the contents of the box are correct according to the model Tools Required This box should also contain the...

Страница 2: ...nstallation instructions Drill bits CL5510 10mm 3 8 25mm 1 Drill bits CL5520 10mm 3 8 12mm 15 32 16mm 5 32 20mm 25 32 Hammer mallet Philips screwdriver Chisel 25mm 1 Stanley knife Adhesive tape pencil...

Страница 3: ...talled Place the long spindle in the front plate socket and using finger grip only test that the spindle is easily moved 80 in both directions Leave socket in the centred position Enter the factory Ma...

Страница 4: ...me OTHER OPTIONS Alternative functionality can be configured for the REM connections including support for connection to dry contact door sensors For further information please refer to the online doc...

Страница 5: ...ck case key will double throw the deadbolt retract the deadbolt and retract the latchbolt without the code When deadbolt is thrown it denies access by code The anti panic feature allows the inside han...

Страница 6: ...70mm 23 4 latch and tape it to the door with the top in line with the height line Mark the holes to be drilled Mark the centre line of latch on to the door edge Apply the template to the other side o...

Страница 7: ...ten the fixing bolts to provide stability 9 Remove the five socket head bolts from the back plate two are found under the battery cover This will release the inside fixing plate 10 Cut the fixing bolt...

Страница 8: ...E ALIGNMENT INSERT 14 Connect the cables storing any excess cable within the door Then install the batteries 15 Fit the back plate over the fixing plate using the four socket head screws 16 Fit the cy...

Страница 9: ...25 32 hole centred over the mark for spindle hole Using the gasket as a template mark the 3 x 8mm 5 16 holes for the through fixing bolts Repeat on the other side of the door 4 Drill the 2 x 20mm 25...

Страница 10: ...ide and remove the set screws from that side DO NOT remove the set screws from both sides The outside handle will now retract the latchbolt but not the deadbolt The inside handle will now simultaneous...

Страница 11: ...https codelocks zohodesk eu portal en kb articles cl5500 installation instructions...

Страница 12: ...gaskets provide friction against the door so that it is not necessary to over tighten the bolts to provide stability 9 Remove the five socket head bolts from the back plate two are found under the bat...

Страница 13: ...ight line with the arrow heads aligned with the centre line Mark the fixing holes and draw around the apertures for the latchbolt and the deadbolt Chisel out the latch aperture to 12mm 1 2 deep and th...

Страница 14: ...https codelocks zohodesk eu portal en kb articles cl5500 installation instructions II CL5500 v1 0516 2019 Codelocks Ltd All rights reserved...

Отзывы: