background image

WARNING!

SIREN PRODUCTS:

This equipment is intended for use by authorized personnel only.  It is the user’s responsi-
bility to understand and obey all laws regarding emergency warning devices.  The user
should check all applicable city, state and federal laws and regulations.
Public Safety Equipment, Inc., assumes no liability for any loss resulting from the use of
this warning device.
Proper installation is vital to the performance of the siren and the safe operation of the
emergency vehicle.  It is important to recognize that the operator of the emergency vehicle
is under psychological and physiological stress caused by the emergency situation.  The
siren system should be installed in such a manner as to: A) Not reduce the acoustical
performance of the system, B) Limit as much as practical the noise level in the passenger
compartment of the vehicle, C) Place the controls within convenient reach of the operator
so that he can operate the system without losing eye contact with the roadway.
Emergency warning devices often require high electrical voltages and/or currents.  Prop-
erly protect and use caution around live electrical connections.  Grounding or shorting of
electrical connections can cause high current arcing, which can cause personal injury and/
or severe vehicle damage, including fire.
PROPER INSTALLATION COMBINED WITH OPERATOR TRAINING IN THE PROPER
USE OF EMERGENCY WARNING DEVICES IS ESSENTIAL TO INSURE THE SAFETY
OF EMERGENCY PERSONNEL AND THE PUBLIC.

Unpacking and Preinstallation

Carefully unpack the unit and check the contents against the parts list on page #6 of this booklet.  Report any damage to carrier
immediately.

3

Installation and Mounting

!

WARNING!

!

Larger wires and tight connections will provide longer service life for components.  For high
current wires it is highly recommended that terminal blocks or soldered connections be used
with shrink tubing to protect the connections.  Do not use insulation displacement
connectors (e.g. 3M

®

 Scotchlock type connectors).  Route wiring using grommets and

sealant when passing through compartment walls.  Minimize the number of splices to
reduce voltage drop.  High ambient temperatures (e.g. underhood) will significantly reduce
the current carrying capacity of wires, fuses, and circuit breakers.  Use "SXL" type wire in
engine compartment.  All wiring should conform to the minimum wire size and other
recommendations of the manufacturer and be protected from moving parts and hot
surfaces.  Looms, grommets, cable ties, and similar installation hardware should be used to
anchor and protect all wiring.
Fuses or circuit breakers should be located as close to the power takeoff points as possible
and properly sized to protect the wiring and devices.
Particular attention should be paid to the location and method of making electrical
connections and splices to protect these points from corrosion and loss of conductivity.
Ground terminations should only be made to substantial chassis components, preferably
directly to the vehicle battery.
The user should install a fuse sized to approximately 125% of the maximum Amp capacity
in the supply line to protect against short circuits.  For example, a 30 Amp fuse should
carry a maximum of 24 Amps.  DO NOT USE 1/4" DIAMETER GLASS FUSES AS THEY
ARE NOT SUITABLE FOR CONTINUOUS DUTY IN SIZES ABOVE 15 AMPS.  Circuit
breakers are very sensitive to high temperatures and will "false trip" when mounted in hot
environments or operated close to their capacity.

Содержание FM100C

Страница 1: ...equipment INSTALLATION OPERATION MANUAL MODEL FM100C OR FM100V Patent Pending SPEAKER FLUSHMOUNT Contents Introduction 2 Unpacking Pre Installation 3 Installation Mounting 3 Maintenance 4 Cleaning 4 Changing Drivers 5 Troubleshooting 5 Parts List Replacement Parts Exploded View 6 Warranty Product Returns 7 IMPORTANT Model FM100 ...

Страница 2: ...cy warning signal Never take the right of way for granted It is your responsibility to be sure you can proceed safely before entering an intersection driving against traffic responding at a high rate of speed or walking on or around traffic lanes The effectiveness of this warning device is highly dependent upon correct mounting and wiring Read and follow the manufacturer s instructions before inst...

Страница 3: ...rrier immediately 3 Installation and Mounting WARNING Larger wires and tight connections will provide longer service life for components For high current wires it is highly recommended that terminal blocks or soldered connections be used with shrink tubing to protect the connections Do not use insulation displacement connectors e g 3M Scotchlock type connectors Route wiring using grommets and seal...

Страница 4: ...void dam age during installation In addition DO NOT TIGHTEN the mounting screws completely until the speaker is parallel and evenly positioned with the holes on the vehicles exterior 5 Connect the wires from the speaker assem bly to the leads coming from the siren control head NOTE When two or more speakers are to be operated by the same control head the speakers must be connected in phase In orde...

Страница 5: ... in the installation and mounting section in this booklet Make sure the wires are tightly sealed at all exit points from the speaker assembly Fill any voids with silicone caulking NOTE When reassembling the speaker make sure to align the drain holes on the driver driver cover and driver cap the drain hole on the Atlas driver is located behind a metal tag These holes should be oriented to the base ...

Страница 6: ...of speaker bracket Parts Exploded Views Parts Shown in Fig 2 1 Coated Mounting Bracket S35470 2 Trim Bezel T03776 Ref Number Description Part No 3 Speaker wire Assemblies T04346 T04347 4 Speaker Screws T06519 5 Speaker Horn S85477 6 Driver Cover T03739 7 100w Siren Driver T03470 8 Driver Cap S85478 9 Nose Cone Screw T09204 Ref Number Description Part No Self Tapping Thread Clearing ...

Страница 7: ...NOTES ...

Страница 8: ...appropriate or inadequate wiring or circuit protection causes this warranty to become void Failure or destruction of the product resulting from abuse or unusual use and or accidents is not covered by this warranty PSE shall in no way be liable for other damages including consequential indirect or special damages whether loss is due to negligence or breach of warranty PSE MAKES NO OTHER EXPRESS OR ...

Отзывы: