18
2.3 Fuse Protect settings
LINUS10 is shipped with the Fuse Protection set to 24A.
To change the Fuse Protect level:
Move to device information page on the display.
Press ,,ESC" button for min 2 seconds, hold it and press aditionally:
- UP button: strong fuse (24 A)
- DOWN button: weak fuse (18 A)
Amplifier needs to be rebooted.
LINUS10
2. THE AMPLIFIER
The front
1 Display
5 Standby power switch
9 Ethernet connection LED
2 Navigational buttons
6 Knurled grill screw
10 DAN LED - (not used)
3 Channel mute buttons
7 LINET connection LED
11 Mains connection LED
4 Rotary encoder knob
8 LEDs
The rear
12 AC power connector
16 XLR - line link outputs
19 LINET network connections
13 SpeakON connectors
(passive loop-through)
1 x IN / 1 x LINK (AES/EBU)
14 Cooling air outlet vents
17 Ethernet connector for remote access 20 AUX connection (alarm override)
15 XLR - line inputs
18 Sensor connection
21 Digital audio network connection (not used)