background image

15

Nothing

Comes Close to a Cobra

14

Turning Your Inverter On or Off

Be sure to have your power inverter properly installed
before attempting to turn the unit

on

(see installation

page 6).

To turn the power inverter on:

1.

If a DC power supply is being used as the power
source, switch it

on

.

2.

On the

Output End

, press the

Power Button

to

on

.

The inverter is now ready to deliver AC power to your loads.
If several loads are to be operated by the inverter, turn
them

on

separately, after the inverter has been turned

on

.

This will ensure that the inverter does not have to deliver
the starting currents required for all the loads at once.

NOTE

The

Power Button

turns the control circuit

in the inverter

on

and

off

. It

does not

disconnect

power from the inverter.

When the button is in the

off

position, the inverter

draws no current from the battery. When it’s in the

on

position, but no power is being supplied to a

load, the inverter draws less than 600 milliamperes
from the battery. This is low current draw. It would
take more than a week to discharge a 100 ampere-
hour battery at this rate depending on the age of
the battery.

Remote On/Off Switch

An optional

Remote On/Off Switch

(see page 24 to order

accessories) can be connected to the

Remote Jack

allowing you to turn the Cobra power inverter

on

or

off

from a convenient location when the inverter is installed
in an out of reach location.

Power On and Off

Operation

Remote On/Off Switch

Operation

Power Button

Remote Switch

Remote Jack

Содержание CPI 2575

Страница 1: ...ssistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m C...

Страница 2: ...dicators 16 Operating Limits 19 Troubleshooting Guide 20 Specifications 21 Warranty Warranty 22 Customer Assistance Maintenance 23 Product Service 23 Accessories and Order Form 24 Remote On Off USB Po...

Страница 3: ...ge to the unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compar...

Страница 4: ...y packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of battery...

Страница 5: ...m back from the end exposing the bare copper The other end of the cable which connects to the power source must be terminated with a lug or other connector that provides a secure low resistance connec...

Страница 6: ...ation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will...

Страница 7: ...volts If you must use longer cables choose thicker cables such as 2 AWG and trim the ends of the cable to fit the terminals To connect the cables between the inverter and the battery 1 Press the Powe...

Страница 8: ...hly ventilate the battery compartment before making this connection b Connect the cable from the Positive Red Terminal of the inverter to the Positive Terminal of the power source the battery s main f...

Страница 9: ...ll be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the total estimated running time in...

Страница 10: ...ower Button turns the control circuit in the inverter on and off It does not disconnect power from the inverter When the button is in the off position the inverter draws no current from the battery Wh...

Страница 11: ...self The meter will flash as shown to indicate Short Circuit Protect and an alarm will sound To restore normal operation disconnect the short circuit and turn the unit Off and On again using the Power...

Страница 12: ...f the input voltage drops below 10 3V 0 3V This protects the battery from being over discharged It will restart when the input voltage exceeds 12V 0 3V The inverter will also shut down if the input vo...

Страница 13: ...eed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Troubleshooting Guide Operation Problem Symptom Low output voltage No output voltag...

Страница 14: ...nce and Product Service Customer Assistance Limited Two Year Warranty For Products Purchased in the U S A Cobra Electronics Corporation warrants that its Cobra power inverter and the component parts t...

Страница 15: ...this order form to fax number 773 622 2269 Or call 773 889 3087 Press 1 from the main menu 8 00 a m to 6 00 p m CT Monday through Friday Make check or money order payable to Cobra Electronics Attn Ac...

Отзывы: