background image

3

Nothing

Comes Close to a Cobra

2

Important Safety Information

Introduction

WARNING

Power inverters contain components

that tend to produce arcs or sparks. To prevent
fire or explosion, do not install the inverter in
areas or compartments containing batteries or
flammable materials or in locations that require
ignition-protected equipment.

WARNING

To reduce the risk of fire, do not cover

or obstruct the ventilation openings. Do not install
inverter in zero-clearance compartment.

Caution: Rechargeable Appliances

Certain chargers for small nickel cadmium batteries
can be damaged if connected to the Cobra 2500 watt
inverter. Two particular types of equipment are
prone to this problem:

1.

Small battery-operated appliances
such as flashlights, razors, and
night lights that can be plugged
directly into an AC receptacle to
recharge.

2.

Certain battery chargers for
battery packs used in hand
power tools. These chargers have
a

WARNING

label stating that

dangerous voltages are present
at the battery terminals.

This problem does not occur with the vast majority of
battery operated equipment. Most use a separate charger
or transformer that is plugged into the AC receptacle and
produces a low voltage output. If the label on the AC
adapter or charger states that it produces a low voltage
AC or DC output (less than 30 volts), the inverter will
have no problem powering the adapter safely.

Cobra 2500 Watt Output Waveform

Some very sensitive electronic equipment may not operate
satisfactory on “square wave” or “modified sine wave.”

The output waveform is referred to as “square wave” or
“modified sine wave.” It is a stepped waveform designed
to have characteristics similar to the sine wave shape of
utility power.

A waveform of this nature is suitable for most AC loads
(including linear and switching power suppliers used in
electronic equipment, transformers and motors).

Important Safety Information

Introduction

Plug In Directly

Dangerous Voltages

Содержание CPI 2575

Страница 1: ...ssistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m C...

Страница 2: ...dicators 16 Operating Limits 19 Troubleshooting Guide 20 Specifications 21 Warranty Warranty 22 Customer Assistance Maintenance 23 Product Service 23 Accessories and Order Form 24 Remote On Off USB Po...

Страница 3: ...ge to the unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compar...

Страница 4: ...y packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of battery...

Страница 5: ...m back from the end exposing the bare copper The other end of the cable which connects to the power source must be terminated with a lug or other connector that provides a secure low resistance connec...

Страница 6: ...ation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will...

Страница 7: ...volts If you must use longer cables choose thicker cables such as 2 AWG and trim the ends of the cable to fit the terminals To connect the cables between the inverter and the battery 1 Press the Powe...

Страница 8: ...hly ventilate the battery compartment before making this connection b Connect the cable from the Positive Red Terminal of the inverter to the Positive Terminal of the power source the battery s main f...

Страница 9: ...ll be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the total estimated running time in...

Страница 10: ...ower Button turns the control circuit in the inverter on and off It does not disconnect power from the inverter When the button is in the off position the inverter draws no current from the battery Wh...

Страница 11: ...self The meter will flash as shown to indicate Short Circuit Protect and an alarm will sound To restore normal operation disconnect the short circuit and turn the unit Off and On again using the Power...

Страница 12: ...f the input voltage drops below 10 3V 0 3V This protects the battery from being over discharged It will restart when the input voltage exceeds 12V 0 3V The inverter will also shut down if the input vo...

Страница 13: ...eed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Troubleshooting Guide Operation Problem Symptom Low output voltage No output voltag...

Страница 14: ...nce and Product Service Customer Assistance Limited Two Year Warranty For Products Purchased in the U S A Cobra Electronics Corporation warrants that its Cobra power inverter and the component parts t...

Страница 15: ...this order form to fax number 773 622 2269 Or call 773 889 3087 Press 1 from the main menu 8 00 a m to 6 00 p m CT Monday through Friday Make check or money order payable to Cobra Electronics Attn Ac...

Отзывы: