Cobra CPI 2575 Скачать руководство пользователя страница 6

7

Nothing

Comes Close to a Cobra

6

Mounting

Installation Requirements

The inverter must be installed in an area that meets all
of the following requirements:

A. Dry

Do not place in an area where water can drip
or splash on the inverter.

B. Cool

Ambient air temperature should be between 30°F
and 105°F (0°C and 40°C). The cooler the better.

C. Ventilate

Allow at least one inch (three cm) of clearance around
the inverter for proper airflow. Make sure that ventilation
openings on the ends of the unit are not obstructed.

D. Safe

Do not install the inverter in the same compartment
as a battery or in any compartment that contains
flammable liquids such as gasoline.

E. Close to Battery

Install unit as close to battery as possible (without
being in the same compartment) to minimize the
length of cable required to connect the inverter to
the battery. It is better and cheaper to run longer
AC wires than longer DC wires (cables).

CAUTION

To avoid fire, do not cover or

obstruct ventilation openings. Do not install
inverter in a zero-clearance compartment.
Overheating may result.

CAUTION

The inverter must only be connected to

batteries with a nominal output voltage of 12 volts.
It will not work with a 6 volt battery, and will be
damaged if it is connected to a 16 volt battery.

WARNING

This unit contains components

which can produce arcs or sparks. To prevent
fire or explosion, do not install in compartments
containing a battery or flammable materials,
or in a location which requires ignition
protected equipment.

WARNING

This unit is suitable for installation

in negative ground applications only. Do not
attempt to install to a positive ground application.

Mounting

To mount your inverter:

1.

Place the inverter on a flat surface with the
mounting bracket against the mounting surface.

2.

Mount to secure surface using mounting hardware
that is corrosion resistant (not included).

The inverter can be mounted horizontally or vertically.
If mounted vertically, neither end of the unit should be at
the top (to avoid foreign material from falling or settling
into the unit).

Installation

Installation
Requirements

Installation

Mounting Hardware

Mounting Brackets

Содержание CPI 2575

Страница 1: ...ssistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a week 773 889 3087 phone Customer Assistance Operators English and Spanish 8 00 a m to 6 00 p m C...

Страница 2: ...dicators 16 Operating Limits 19 Troubleshooting Guide 20 Specifications 21 Warranty Warranty 22 Customer Assistance Maintenance 23 Product Service 23 Accessories and Order Form 24 Remote On Off USB Po...

Страница 3: ...ge to the unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compar...

Страница 4: ...y packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the vast majority of battery...

Страница 5: ...m back from the end exposing the bare copper The other end of the cable which connects to the power source must be terminated with a lug or other connector that provides a secure low resistance connec...

Страница 6: ...ation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will...

Страница 7: ...volts If you must use longer cables choose thicker cables such as 2 AWG and trim the ends of the cable to fit the terminals To connect the cables between the inverter and the battery 1 Press the Powe...

Страница 8: ...hly ventilate the battery compartment before making this connection b Connect the cable from the Positive Red Terminal of the inverter to the Positive Terminal of the power source the battery s main f...

Страница 9: ...ll be running between battery charging cycles 3 Calculate the total watt hours of energy consumption power x operating time using the average power consumption and the total estimated running time in...

Страница 10: ...ower Button turns the control circuit in the inverter on and off It does not disconnect power from the inverter When the button is in the off position the inverter draws no current from the battery Wh...

Страница 11: ...self The meter will flash as shown to indicate Short Circuit Protect and an alarm will sound To restore normal operation disconnect the short circuit and turn the unit Off and On again using the Power...

Страница 12: ...f the input voltage drops below 10 3V 0 3V This protects the battery from being over discharged It will restart when the input voltage exceeds 12V 0 3V The inverter will also shut down if the input vo...

Страница 13: ...eed of the fan increases as the load increases The unit is completely insulated in input and output for added safety Troubleshooting Guide Operation Problem Symptom Low output voltage No output voltag...

Страница 14: ...nce and Product Service Customer Assistance Limited Two Year Warranty For Products Purchased in the U S A Cobra Electronics Corporation warrants that its Cobra power inverter and the component parts t...

Страница 15: ...this order form to fax number 773 622 2269 Or call 773 889 3087 Press 1 from the main menu 8 00 a m to 6 00 p m CT Monday through Friday Make check or money order payable to Cobra Electronics Attn Ac...

Отзывы: