Cobra cf4 Скачать руководство пользователя страница 6

Location 

1.  This appliance must be installed in a suitably  

ventilated room to prevent dangerous build up 
of combustion products. 

2.  Installation must allow for a sufficient flow of 

fresh air for the combustion air supply. 

 

Combustion Air Requirements 

Natural Gas   

24 m³/hr minimum. 

LPG / Propane 

24 m³/hr minimum. 

 
3.  Position the appliance in its approximate 

working position. 

4.  All air for burner combustion is supplied from 

underneath the appliance.  The legs must 
always be fitted and no obstructions placed on 
the underside or around the base of the 
appliance, as obstructions will cause incorrect 
operation and / or failure of the appliance. 

5.  Components having adjustments protected 

(e.g. paint sealed) by manufacturer are only 
allowed to be adjusted by an qualified service 
agent.  They are not to be adjusted by the  
installation person. 

 

NOTE: 
Do not obstruct or block the appliances flue.  Never 
directly connect a ventilation system to the 

 

appliance flue outlet. 
 

 

Clearances 

NOTE: 
Only non-combustible materials can be used in 
close proximity to this appliance. 
In order to facilitate easy operation, drainage and 
servicing of the appliance, a minimum of 600 mm 
clearance should be maintained at the front of the 
appliance. 
 
Any gas burning appliance requires adequate 
clearance and ventilation for optimum and trouble-
free operation.  The following minimum installation 
clearances are to be adhered to:- 

 

Part 3  Installation 

Installation Requirements 

NOTE: 

It is most important that this appliance is installed 
correctly and that operation is correct before use.  
Installation shall comply with local, gas, health and 
safety requirements. 
This appliance shall be installed with sufficient  
ventilation to prevent the occurrence of 

 

unacceptable concentrations of health harmful  
substances in the room, the appliance is installed in. 
 
Cobra gas fryers are designed to provide years of 
satisfactory service and correct installation is  
essential to achieve the best performance,  
efficiency and trouble-free operation. 
This appliance must be installed in accordance with 
National installation codes and in addition, in  
accordance with relevant National / Local codes 
covering gas and fire safety. 
 
Australia: 

AS 5601- Gas Installations. 

New Zealand: 

NZS 5261- Gas Installation. 

United Kingdom:  Gas Safety (Installation and Use) 

Regulations 1998. 

Ireland: 

IS 820 - Non Domestic Gas  
Installations. 

 
Installations must be carried out by qualified service 
persons only.  Failure to install equipment to the 
relevant codes and manufacturer’s specifications 
shown in this section will void the warranty. 
Components having adjustments protected (e.g. 
paint sealed) by manufacturer, are only allowed to 
be adjusted by an qualified service agent. They are 
not to be adjusted by the installation person. 
 
 

Unpacking 



Remove all packaging and transit protection 
from the appliance including all protective  
plastic coating from the door outer panel and  
exterior stainless steel panels. 



Check equipment and parts for damage.  
Report any damage immediately to the carrier 
and distributor. 



Report any deficiencies to the distributor who  
supplied the appliance. 



Check that the available gas supply is correct to 
that shown on the rating plate located on the 
inside of the access door. 



Check that the following parts have been 
supplied with the appliance:- 

 
 

Baskets 2 
Basket Trays 

Lid 1 

 

Combustible 

Surface 

Non Combustible 

Surface 

LH / RH 

Side 

150 mm 

0 mm 

Rear 

150 mm 

0 mm 

Содержание cf4

Страница 1: ...I N S T A L L A T I O N A N D O P E R A T I O N M A N U A L 230114 9 400mm Gas Fryer Model CF4 For use in GB IE ...

Страница 2: ...00 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 3...

Страница 3: ... Single Tank 21 Ltr Part 1 Introduction 2 Part 2 Specifications 3 Part 3 Installation 4 Part 4 Operation 7 Part 5 Cleaning and Maintenance 11 Part 6 Wiring Schematic 13 Part 7 Gas Conversion 14 Part 8 Replacement Parts List 17 ...

Страница 4: ...NSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE ...

Страница 5: ...ntroller which controls both pilot and main burners This Fryer is fitted with an Over Temperature Safety Cut Out system with Full Flame Failure Safety Controls Thermostatically regulated gas controls with snap action thermostat sensitive to changes in oil temperature which improves both recovery and output An open tank design to make cleaning a simple and easy task Gas Supply Requirements Non UK O...

Страница 6: ...safety requirements This appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of health harmful substances in the room the appliance is installed in Cobra gas fryers are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance efficiency and trouble free operation This applia...

Страница 7: ... Assembly This model is delivered completely assembled Ensure that the legs are securely attached NOTE This appliance is fitted with adjustable feet to enable the appliance to be positioned securely and level This should be carried out on completion of the gas connection Refer to the Gas Connection section Gas Connection NOTE ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED SERVICE PERSON 1...

Страница 8: ...peration and shutdown procedures for the appliance 2 This manual must be kept by the owner for future reference and a record of Date of Purchase Date of Installation and Serial Number of Unit recorded and kept with this manual These details can be found on the Rating Plate attached to the inner R H side of the front access door panel NOTE If for some reason it is not possible to get the appliance ...

Страница 9: ...fety protection 2 Improper operation is therefore almost impossible however bad operation practices can reduce the oil shortening life and produce a poor quality product To use this fryer correctly please read the following sections carefully Filling the Tank Lighting the Pilot Burners Lighting the Main Burners Setting the Operating Temperature Draining and Cleaning Single Tank CF4 Controls CAUTIO...

Страница 10: ... gas supply is turned on 2 Check that no foreign articles are in the tank Filling the Tank NOTE Cobra fryers can be used with both oil and shortening 1 Before filling the tank always check that the drain valve s behind the access door is closed A locking slide is provided on this valve and this should always be locked in position during use a OIL Carefully fill fryer tank with oil until the FILL L...

Страница 11: ...um should be at the correct temperature for the food to be cooked before lowering the food into the tank Avoid heating the frying medium to any higher temperature than is recommended Also avoid holding the frying medium at the frying temperature when there is no food being cooked Any frying medium will break down if held for long periods at frying temperatures Part 4 Operation Lighting the Main Bu...

Страница 12: ...eces are cooked through 6 he exact cooking time depends upon the size of the food pieces and upon whether the food has been pre cooked When in doubt test a sample and be sure 7 Remove the food from the frying medium and allow the food to drain in the basket over the fryer 8 Conserve the excess frying medium by letting it drain back into the fryer This draining should not consume much time if the f...

Страница 13: ...ults occur have them attended to promptly Don t wait until they cause a complete breakdown It is recommended that the appliance is serviced every 6 months Clean the fryer regularly A clean fryer looks better will last longer and will perform better NOTE DO NOT use abrasive detergents sharp scrapers strong solvents or caustic detergents as they could corrode or damage the fryer Ensure that any dete...

Страница 14: ...acle 7 When the tank is empty use a small tank with a handle as a ladle and dip into the hot frying medium from receptacle and pour vigorously around sides and bottom of the tank to wash out crumbs and particles adhering to them Continue to dip and pour until all crumbs are washed down and into the filter bag 8 Open drain valve fully check for any particles or crumb residue lodged in the valve Cle...

Страница 15: ...13 Part 6 Wiring Schematic CF4 GAS FRYER Wiring Schematic ...

Страница 16: ...he gas valve to reveal the Pilot Adjustment Screw See Gas Specifications table for adjustment details and the Low Fire Blanking Screw Screwed fully In 5 Connect a manometer to the Inlet pressure test point Line Pressure on the gas control valve located on the underside of the valve Turn on the gas supply and ensure that the pressure is within the specification shown in the Gas Specifications Table...

Страница 17: ...onversion replace the gas type identification label located at The rear of the appliance above the gas connection Beside the Rating Plate NOTE Pin rotated for Natural Gas NOTE Pin rotated for LPG Commissioning Before leaving the converted installation 1 Check all gas connections for leakages using soapy water or other gas detecting equipment 2 Check the following functions in accordance with the o...

Страница 18: ...0 mm Ø 1 80 mm Pilot Burner Injectors 0 62 0 35 Pilot Screw Adjustment Fully Out c c w Fully Out c c w Low Fire Screw Adjustment Fully Out c c w Flush with casing Fully Out c c w Flush with casing Burner Operating Pressure 0 8 kPa 2 5 kPa Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Natural Gas G20 Propane G31 Main Burner Injectors Ø 3 00 mm Ø 1 80 mm Pilot Burner Injectors 0 62 0 35 Pilot Screw Ad...

Страница 19: ...alve 228531 Regulator Natural Gas LP Gas Propane Convertible BSP F F General 018019 Fryer Basket 227856 Door Magnet 227466 Door Catch Receiver 229958 Door Handle 019390 Drain Valve 230116 Drain Extension 230461 Basket Grid 234059 Adjustable Leg 150 mm 229674 Rear Roller Assy 230117 Fryer Lid Gas Conversion Kits Optional Extras 18176 Drain Stick Optional Extra Only Part 7 Replacement Parts List IMP...

Страница 20: ......