6.2.2 DIGImini LED Troubleshooting
The DIGImini repeater includes six LEDs on its front panel (see section
1.7.1). The following table
provides a description of the LED troubleshooting procedures.
Indicator
Description
Band Specific LED
(i.e 900/1800/2100)
One Indicator per band :
RED
Steady - service muted due to general fault
Blinking – service muted by user
ORANGE
Blinking – service initiating on power up or reset
Steady – high DL/UL signal or VSWR
GREEN and
ORANGE
Blinking- Reduced gain by IMOP
GREEN
Blinking – DL power below threshold
Steady - normal service operation
(Ethernet) MNG
Relevant only if connected to DMCU:
Green Blinking – normal operation of CCD
(Ethernet) Modem
Relevant only if connected to DMCU:
•
Green Steady - modem is either not defined, or defined modem
is operating normally.
•
Orange Steady– modem is trying to connect
•