List of events
98-165591-B
Appendix B: System messages
B-8
BBBB
B.2.2
Events from antenna
Event ID
Severity
Description
Explanation
0A001-0 ERROR
Production data Production data is invalid.
0A002-0 ERROR
XIM internal
Antenna configuration data stored in the PCM module is
invalid.
0A003-0 ERROR
XIM external
Antenna configuration data stored in the VIM module is
invalid.
0A004-0 ERROR
XIM I/X match
Antenna configuration data stored in the PCM module does
not match the configuration data stored in the VIM module.
0A005-0 ERROR
Antenna type
The configured antenna type is not supported or unknown.
0A006-0 ERROR
PCM FPGA load The PCM FPGA cannot be initialised and loaded correctly.
0A007-0 ERROR
XIM FPGA load
The VIM FPGA cannot be initialised and loaded correctly.
0A008-0 ERROR
XIM production Production/calibration data stored in the VIM module is
invalid.
0A00A-0 ERROR
GNSS
initialisation
The GNSS device cannot be initialised. Check cable and GNSS
device.
0A014-0 ERROR
AMB device
discovery
Missing one or more of the following devices: ISM,
DDM/DMD/FDM and PMM. Check cables.
0A015-0 ERROR
Azi DDM ABS
device
Cannot initialise the azimuth DDM/DMD/FDM. Info:
0x00000000: Device not found (possible cabling problem)
0x0000bbaa: Device internal error (replace device)
aa=status, bb=state.
0A016-0 ERROR
Xel DDM ABS
device
Cannot initialise the cross-elevation DDM/DMD/FDM. Info:
See 0A015-0.
0A017-0 ERROR
Ele DDM ABS
device
Cannot initialise the elevation DDM/DMD/FDM. Info: See
0A015-0.
0A018-0 ERROR
ISM ABS device Cannot initialise the ISM Info: 0x00000000: Device not
found (possible cabling problem) 0x000cbbaa: Device
internal error (replace device) aa=status, bb=state,
c=calibration data error.
0A019-0 ERROR
PMM ABS
device
Cannot initialise the PMM. Info: See 0A015-0.
0A01A-0 ERROR
BCM ABS
device
Cannot initialise the BCM. Info: See 0A015-0.
0A01E-0 ERROR
Sensor sanity
Too many invalid values measured by the ISM during
initialisation. Check for vibrations or malfunctioning ISM.