![Coastcom D/I Mux III System Скачать руководство пользователя страница 94](http://html.mh-extra.com/html/coastcom/d-i-mux-iii-system/d-i-mux-iii-system_user-manual_2628616094.webp)
Chapter 3. Installation
74
Figure 3-20. V.35 Female Data Circuit
Digital Program Channels
Digital Program Channels (DPCs) can use the 50-pin voice connectors or the DB-25 connectors.
They connect to Tip and Ring for transmit, and Tip 1 and Ring 1 for receive.
Common Equipment and Line Card Installation
All common equipment and line cards are installed in the same manner. Common equipment units
should be installed before line cards, and must be placed in the correct common equipment card slot, as
designated on the static strip. Line cards can be placed in any line card slot of the multiplexer. See the
D/I Mux III front view diagrams in Figures 3-15, 3-16 and 3-17 for the location of the various card slots,
and follow the order given in this chapter for common equipment installation. (See
Appendix F. Shelf
Supplement
, for details on older model shelves.)
Warning!
Power down the shelf when installing or replacing common equipment. Check the static strip in the shelf to
ensure that the card being installed is the correct card for that slot, or damage can result.
Electrostatic Precautions
Precaution must be taken to prevent electrostatic damage to plug-in units. Electrostatic damage
can cause semiconductors and other static-sensitive components to fail, resulting in
unexplainable test failures and degraded performance.
Содержание D/I Mux III System
Страница 20: ......
Страница 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Страница 40: ...Chapter 1 System Overview and Modes of Operation 20 Figure 1 10 Common Control Unit Block Diagram ...
Страница 45: ...Chapter 1 System Overview and Modes of Operation 25 Figure 1 11 AMCU Motherboard Circuit Flow Block Diagram ...
Страница 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Страница 76: ...Chapter 3 Installation 56 Figure 3 8 Backplane for 8 Slot Voice and Data Shelf F Female M Male P N 91620 308 ...
Страница 77: ...Chapter 3 Installation 57 Figure 3 9 Backplane for 12 Slot Voice and Data Shelf F Female M Male P N 91620 312 ...
Страница 78: ...Chapter 3 Installation 58 Figure 3 10 Backplane for 24 Slot Voice and Data Shelf F Female M Male P N 91620 324 ...
Страница 79: ...Chapter 3 Installation 59 ...
Страница 192: ...Chapter 5 Diagnostics 172 Figure 5 2 DB 15 Male T1 Loopback Connector Figure 5 3 RJ 48 T1 Loopback Connector ...
Страница 227: ...D I Mux III User s Manual Appendix A D I Mux III Specifications APPENDIX A D I MUX III SPECIFICATIONS ...
Страница 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Страница 234: ...D I Mux III User s Manual Appendix C Accessories Installation APPENDIX C ACCESSORIES INSTALLATION ...
Страница 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Страница 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Страница 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Страница 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...
Страница 327: ...D I Mux III User s Manual Appendix I Traps and Modem Dial Out Configuration 307 Figure J 20 RJ 48 pin out ...