D/I MUX III User’s Manual
ii
RELEASE NOTE
August 2005
RING GENERATOR MODULE FOR D/I Mux III
Introduction:
The 30333-101 / 121 Ring Generator provides internally generated ringing voltage for AC or DC
powered D/I Mux III shelves with 2W FXS and Smart Omni-Orderwire feature cards. The
30333-101 is a –48 volt powered unit while the 30333-121 is a –24 volt powered unit. It provides
up to 15 watts of continuous, superimposed (ringing voltage referenced to the negative battery
supply voltage) sine wave ringing voltage. The nominal frequency is 20 Hertz. A front panel
green LED indicates the presence of power to the card. A red LED and relay contact closure
indicate generator failure.
Installation:
The 30333-101 / 121 Ring Generator can be installed in any of three available areas of the D/I
Mux III shelf: Power Supply, Feature Card or UCOM (FDLP). In any of the three locations, it
automatically configures itself to operate. It can be installed or removed while the shelf is in
operation (hot swapped).
When installed in the UCOM location the accessory 30333-101-UC cable must be in place on
the back of the shelf to complete installation.
Installation of 30333-101-UC cable.
Note:
this cable is installed only when the Ring
Generator is located in the UCOM (FDLP) card slot. This cable is included with each 30333-
101 or 30333-121 unit.
At the rear of the shelf, plug the 30333-101-UC cable’s DB-25 male connector into the
DB-25 female UCOM2 location. Plug the white Molex connector into the mating shelf
Molex connector marked “AUX SHF I/F”. Unscrew the two screws marked “MNR ALM”
on the screw-down barrier strip. Install the two cable wires with the ring lugs. Put one
under each screw head. Connections for failure alarm are made at this location on the
barrier strip.
DB – 25 – M
MOLEX
WIRE
AMP 205208-1
Shell
39-01-2160
18 AWG
AMP 66570-3
Pins
w/39-00-0039
Insulated
AMP 206478-3
Hood
Female Pins
Hookup,
Pairs
Twisted
Содержание D/I Mux III System
Страница 20: ......
Страница 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Страница 40: ...Chapter 1 System Overview and Modes of Operation 20 Figure 1 10 Common Control Unit Block Diagram ...
Страница 45: ...Chapter 1 System Overview and Modes of Operation 25 Figure 1 11 AMCU Motherboard Circuit Flow Block Diagram ...
Страница 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Страница 76: ...Chapter 3 Installation 56 Figure 3 8 Backplane for 8 Slot Voice and Data Shelf F Female M Male P N 91620 308 ...
Страница 77: ...Chapter 3 Installation 57 Figure 3 9 Backplane for 12 Slot Voice and Data Shelf F Female M Male P N 91620 312 ...
Страница 78: ...Chapter 3 Installation 58 Figure 3 10 Backplane for 24 Slot Voice and Data Shelf F Female M Male P N 91620 324 ...
Страница 79: ...Chapter 3 Installation 59 ...
Страница 192: ...Chapter 5 Diagnostics 172 Figure 5 2 DB 15 Male T1 Loopback Connector Figure 5 3 RJ 48 T1 Loopback Connector ...
Страница 227: ...D I Mux III User s Manual Appendix A D I Mux III Specifications APPENDIX A D I MUX III SPECIFICATIONS ...
Страница 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Страница 234: ...D I Mux III User s Manual Appendix C Accessories Installation APPENDIX C ACCESSORIES INSTALLATION ...
Страница 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Страница 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Страница 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Страница 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...
Страница 327: ...D I Mux III User s Manual Appendix I Traps and Modem Dial Out Configuration 307 Figure J 20 RJ 48 pin out ...