![Coastcom D/I Mux III System Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/coastcom/d-i-mux-iii-system/d-i-mux-iii-system_user-manual_2628616031.webp)
Chapter 1. System Overview and Modes of Operation
11
Trunk Processing
When a local alarm, remote alarm, or system failure causes a Carrier Group Alarm (CGA) to
occur, trunk processing removes line cards from service in the D/I Mux III. When the problem is
cleared, service is restored. Disabling CGA is optional on some line cards. Refer to the individual
user manuals for further description of CGA operation with specific line cards.
T1 Interfaces - CSUs
There are three versions of Dual Channel Service Unit (CSU) interfaces available: T1/DSX-1, T1/T1,
and DSX-1/DSX-1. Each CSU provides slightly different options and capabilities for equalizing output
across twisted-pair cable. This process is called line build-out (LBO). This is required to compensate
for the characteristics of the twisted-pair cable so that the correct signal level and shape is received at
the DSX-1.
With the T1/DSX-1 version, LBO is provided on the T1-1 (network) side, and an equalizing network is
provided on the DSX-1 (terminal) side. This version can be used, for example, between a T1-2 network
and a digital PBX.
The T1/T1 version provides line build-outs on both sides as well as on both T1-1 and T1-2 to interface to
T1 carriers. This version is used in drop-and-insert or dual channel bank applications.
The DSX-1/DSX-1 version provides DSX equalization on both sides. This version is for private networks
which require T1 test capabilities. DSX-1 interfaces work well with transmission equipment such as
microwave radios and fiber optic modems.
Lightning Protection
When installed as an option with a CSU interface unit, lightning protection circuitry is included with the T1
inputs and outputs. It protects against high-voltage surges and spikes on the T1 line only; it does not
provide protection on the line card side.
T1 Testing With the CSU
The Dual CSU interface option provides integrated Channel Service Unit functions for the D/I Mux III T1-
1 and T1-2 transmission paths, along with limited test functions.
A Dual CSU interface installed in a D/I Mux III shelf operates in conjunction with the other common
control units to provide the integrated CSU features. The CSU features are provided for both T1-1 and
T1-2 transmission spans, and include the following:
•
Test loopback, network loopback, and bypass
•
Lightning protection
•
T1 span line build-ou
t
equalization
•
Keep-alive
signal (channel bank mode loopback)
•
Span power can be terminated, looped back, or sent through the shelf
•
Jackfield, for ease of maintenance
Содержание D/I Mux III System
Страница 20: ......
Страница 36: ...Chapter 1 System Overview and Modes of Operation 16 ...
Страница 40: ...Chapter 1 System Overview and Modes of Operation 20 Figure 1 10 Common Control Unit Block Diagram ...
Страница 45: ...Chapter 1 System Overview and Modes of Operation 25 Figure 1 11 AMCU Motherboard Circuit Flow Block Diagram ...
Страница 51: ...Chapter 1 System Overview and Modes of Operation 31 ...
Страница 76: ...Chapter 3 Installation 56 Figure 3 8 Backplane for 8 Slot Voice and Data Shelf F Female M Male P N 91620 308 ...
Страница 77: ...Chapter 3 Installation 57 Figure 3 9 Backplane for 12 Slot Voice and Data Shelf F Female M Male P N 91620 312 ...
Страница 78: ...Chapter 3 Installation 58 Figure 3 10 Backplane for 24 Slot Voice and Data Shelf F Female M Male P N 91620 324 ...
Страница 79: ...Chapter 3 Installation 59 ...
Страница 192: ...Chapter 5 Diagnostics 172 Figure 5 2 DB 15 Male T1 Loopback Connector Figure 5 3 RJ 48 T1 Loopback Connector ...
Страница 227: ...D I Mux III User s Manual Appendix A D I Mux III Specifications APPENDIX A D I MUX III SPECIFICATIONS ...
Страница 232: ...D I Mux III User s Manual Appendix B 24 Volt Systems 212 APPENDIX B 24 VOLT SYSTEMS ...
Страница 234: ...D I Mux III User s Manual Appendix C Accessories Installation APPENDIX C ACCESSORIES INSTALLATION ...
Страница 237: ...D I Mux III User s Manual Appendix D Preconfigured Maps APPENDIX D PRECONFIGURED MAPS ...
Страница 243: ...D I Mux III User s Manual Appendix E SNMP APPENDIX E SNMP ...
Страница 265: ...D I Mux III User s Manual Appendix G Modem Interfaces APPENDIX G MODEM INTERFACES ...
Страница 284: ...D I Mux III User s Manual Appendix H Set Report Options APPENDIX H SET REPORT OPTIONS ...
Страница 327: ...D I Mux III User s Manual Appendix I Traps and Modem Dial Out Configuration 307 Figure J 20 RJ 48 pin out ...