31
FILTER CYCLE 2
Filter Cycle 2 is OFF by default. Simply navigate to the Filter Cycle 2
line by pressing the Right Navigation Button, and when “NO” is high-
lighted, press Up or Down to toggle Filter Cycle 2 on and off. When Filter
Cycle 2 is ON, it can be adjusted in the same manner as Filter Cycle
1 by navigating to the right. It is possible to overlap Filter Cycle 1 and
Filter Cycle 2, which will shorten overall filtration by the overlap amount.
PURGE CYCLES
In order to maintain sanitary conditions, as well as protect against freez-
ing, secondary water devices will purge water from their respective
plumbing by running briefly at the beginning of each filter cycle.
If the Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2
will initiate a purge when Filter Cycle 2 is programmed to begin.
ADDITIONAL SETTINGS
LIGHT CYCLE OPTION
The Light Timer is OFF by default. The settings can be edited the same
way that Filter Cycles are edited.
INVERT PANEL
Selecting Invert Panel will flip the display and the buttons so the panel
can be easily operated from inside or outside the hot tub.
DEDICATED BUTTONS
SPECIFIC BUTTONS FOR SPECIFIC DEVICES
If the panel has dedicated function buttons (TP800) or the spa has an
Auxiliary Panel(s) installed, pressing those buttons will activate the de-
vice indicated for that button. These dedicated buttons will operate just
like the Spa Screen buttons and the equipment will behave in the same
manner with each button press.
RESTRICTING OPERATION
The control can be restricted to prevent unwanted use or temperature
adjustments. Locking the Panel prevents the controller from being used,
but all automatic functions are still active. Locking the Settings allows
Jets and other features to be used, but the Set Temperature and other
programmed settings cannot be adjusted.
Settings Lock allows access to a reduced selection of menu items.
These include Set Temperature, Invert, Lock, Utilities, Information and
Fault Log. They can be seen, but not changed or edited.
OWNER’S MANUAL
2017
UNLOCKING
An Unlock Sequence using the navigation buttons can be used from the
Lock Screen. The Unlock Sequence is the same for both Panel Lock and
Settings Lock.
ADDITIONAL SETTINGS
HOLD MODE - M037*
Hold Mode is used to disable the pumps during service functions like
cleaning or replacing the filter. Hold Mode will last for 1 hour unless the
mode is exited manually. If spa service will require more than an hour, it
may be best to simply shut down power to the spa.
DRAIN MODE
Some spas have a special feature that allows Pump 1 to be employed
when draining the water. When available, this feature is a component of
Hold Mode.
UTILITIES
The Utilities Menu contains the following:
A/B Temps:
When this is set to On, the temperature display will alternate to
display temperature from Sensor A and Sensor B in the heater.
Demo Mode:
Demo Mode is not always enabled, so it may not appear. This is
designed to operate several devices in a sequence in order to demonstrate the
various features of a particular hot tub.
Fault Log:
The Fault Log is a record of the last 24 faults that can be reviewed
by a service tech.